User Guide

- 13 -
fire
2.Not match nozzle aperture
with gas resources
2.Adjust nozzle
diameter
3.Flow of connection
pipe is not enough
3.Increase pipe’s
allowable flow
4.Damper opening
degree is too large
4.Adjust damper
Yellow flame and
black smoke
1.Use bottom gas
1.Change gas
2.Not match nozzle aperture
with gas resources
2.Adjust nozzle
diameter
3.Not enough air to ignite
3.Increase damper
opening degree
4.In the peak of using
gas, sources of gas
float heavy
4.Turn down valves
flow. Turn it up
after the peak
The problems mentioned above are only for reference. If any fault occurs,
please stop using, and contact technicians to check and repair. Safety first,
turn off the power and gas supply before maintenance.
L
I
S
E
D
T
CM
C US
Intertek
Conforms to ANSI STD Z83.11-2016
Certified to CSA STD 1.8-2016
L
I
S
E
D
T
CM
Intertek
4003935
Conforms to NSF/ANSI STD.4
S
A
N
I
T
A
T
I
O
N
Our products have the advantages of good durability and low maintenance
charge. But to update some components and necessary maintenance, can prolong