Model #of burners and control method FCFS-40 3 pieces Integrated control FCFS-50 FCFS-75 4 pieces Integrated control 5 pieces Integrated control Gas Species Intake-tube Per BTU pressure B.T.U./h (in. W. C.) Total BTU B.T.U./h Nozzle No. Natural Gas 4 34,000 102,000 #36 L.P. Gas 10 30,000 90,000 #52 Natural Gas 4 34,000 136,000 #36 L.P. Gas 10 30,000 120,000 #52 Natural Gas 4 34,000 170,000 #36 L.P. Gas 10 30,000 150,000 #52 5.must be signed by the carrier representative (Driver), and contact the carriers to pursue a claim within 15 days after receiving; Be sure to install supporting legs before using, and do not tear up any label or logo before normal using; Please read these instructions carefully before installation and operation.
6.2、Debugging It’s very important to debug the new stove. Through the comprehensive system test of equipment, we can ensure function and safety performance of products. Discovering any potential problems before use (such as equipment’s placement, ventilation, operation, etc), can avoid costly losses. 7. Safety Notices and Precautions Warning! For your safety, do not place petrol and other flammables nearby. Please keep clean and free of flammables surroundings. (Read ANSI Z83.
manufacturer has dealt with these sharp edges during production, however, we insist the operator take care when in contact with this piece of equipment; Always keep hands, hair and clothing away from heating source. Wait the unit cools down before cleaning. Because the unit is too hot to handle after using. 8. Operating Instructions Before operating, make sure to place the unit horizontally by adjusting bottom adjustable legs. 8.
●Press down safety valve and turn to “OFF”. 8.4、Cooking ●Before using the equipment for the first time, please use a mild detergent to wipe it for cleaning. Do not use corrosive or abrasives detergent.
with clean and mixed detergent clothing, second, wipe it dry with a clean clothing, do not use vinegar or corrosive liquid wiping.
Supplied gas pressure regulator is factory set at 4”Natural Gas W.C, and L.P. Gas pressure is factory set at 10”Natural Gas W.C; Use a pressure gauge which is equipped with liquid (such as U-type pressure gauge, the minimum value is 0.1mbar) or a digital pressure gauge to test. Steps are as following: 1、Open cabinet door, remove needle type pressure joint screw arbor(Fig.
fire 2.Not match nozzle aperture 2.Adjust nozzle with gas resources diameter 3.Flow of connection pipe is not enough 3.Increase pipe’s allowable flow 4.Damper opening degree is too large 4.Adjust damper 1.Use bottom gas 1.Change gas 2.Not match nozzle aperture 2.Adjust nozzle with gas resources diameter Yellow flame and black smoke 3.Increase damper opening degree 4.In the peak of using 4.Turn down valves gas, sources of gas flow.
Email: Warranty@smartkitchenservice.