5) INSTALLATION INSTRUCTION
If the carton appears damaged, or damage is discovered once the carton is opened, stop
immediately and contact the freight company to file a damage claim.
1. Remove all external packaging that is protecting top portion of unit
2. Remove all internal packaging to the unit, if present.
3. Visually inspect all external and internal portions of unit for damage.
4. Wipe down the exterior of the unit using a damp cloth with warm water. Do not use abrasive pads or
cleaners as they will damage the stainless steel surface.
Note: Ambient Conditions - Make sure that the operating location is in an area where the
ambient temperature is held constant (minimum 70°F). Please avoid areas such as near exhaust
fans and air conditioning ducts.
Warning! Operating environment
Ensure that operation location is at a reasonable distance from combustible walls and materials
otherwise combustion or discoloration could occur.
Caution! Operating environment
Place unit on a stable, level floor. The unit must be level, both front and back and left to right, in
order to maintain an equal water depth throughout the wells. To eliminate rocking or adjust
height turn the adjustable feet in the proper direction until the desired results are obtained.
Note: Maximum adjustment is 1 inch
5. Before plugging unit into wall outlet or permanently electrical connecting, the unit should be
adjusted to the desired height and align with other equipment.
6. The voltage and wattage ratings of this steam table are given on the device nameplate. Connect the
steam table to a circuit having a voltage and type of current similar to that stamped on the device
nameplate. For movable equipment a proper cord and plug are included for connection to the
matching power supply outlet.
7. Plug unit into grounded electrical outlet with correct voltage, and plug configuration.
a. Warning! Using any receptacle that is not designed to match the attached cord and plug
MAY cause personal injury and WILL void your warranty. Please attach the Steam Table, to
an individual branch circuit
8. For permanent installations, connections to supply line may be made through conduit or armored
cable. Use copper wire for power supply or suitable copper to aluminum wire connector.
9. The body of the appliance should be grounded by connecting the ground stud provided in the
junction box to a good electrical ground.
10. The steam table is not fused and consequently must be connected to a fused circuit equipped with
suitable disconnect means, as required by local code authorities.
11. To assembly the units follow steps 1 thru 6 listed below.