Installation Instructions
Table Of Contents
- Table of Contents
- Table des matières
- Range Hood Safety
- installation requirements
- Installation Instructions
- Prepare Location
- Prepare In-Line Smart Kit
- Install In-Line Smart Kit KVWB40DS Series Range Hoods
- Complete Installation
- Make Electrical Connection
- Install In-Line Smart Kit KVUB60DS Series Range Hoods
- Complete Installation
- Make Electrical Connection
- Install In-Line Smart Kit JXW85DS, JXI85DS, KVWB60DS, and KVIB60DS Series Range Hoods
- Complete Installation
- Make Electrical Connection
- Install In-Line Smart Kit WVW75UC and WV175UC Series Range Hoods
- Complete Installation
- Make Electrical Connection
- wiring diagram
- sÉcuritÉ de la hotte de cuisiniÈre
- Exigences d’installation
- Instructions d’installation
- Préparation de l’emplacement
- Préparation du ventilateur déporté intelligent
- Installation du ventilateur déporté intelligent Hottes série KVWB40DS
- Achever l’installation
- Raccordement électrique
- Installation du ventilateur déporté intelligent Hottes série KVUB60DS
- Achever l’installation
- Raccordement électrique
- Installation du ventilateur déporté intelligent Hottes série JXW85DS, JXI85DS, KVWB60DS et KVIB60DS
- Achever l’installation
- Raccordement électrique
- Installation du ventilateur déporté intelligent Hottes série WVW75UC et WV175UC
- Achever l’installation
- Raccordement électrique
- schÉma de cÂblage
30
Make Electrical Connection
Connect Range Hood and In-Line Smart Kit
1. Install the UL listed or CSA approved strain reliefs (3) in the
range hood and In-Line Smart Kit electrical knockouts.
2. Measure the distance between the In-Line Smart Kit and the
range hood terminal box.
3. Install 8 - 14 AWG wires with an insulating sleeve or conduit
between the terminal box and UL listed strain reliefs.
4. Connect together the set of 8 wires in the In-Line Smart Kit
terminal box.
5. Connect together the set of 8 wires in the range hood
terminal box.
Connect In-Line Smart Kit
Electrical Connection In-Line Smart Kit
1. Use a UL listed or CSA approved wire connector to connect
the black wires together.
2. Use a UL listed or CSA approved wire connector to connect
the white wires together.
3. Use a UL listed or CSA approved wire connector to connect
the red wires together.
4. Use a UL listed or CSA approved wire connector to connect
the blue wires together.
5. Use a UL listed or CSA approved wire connector to connect
the gray wires together.
6. Use a UL listed or CSA approved wire connector to connect
the brown wires together.
7. Use a UL listed or CSA approved wire connector to connect
the yellow wires together.
8. Use a UL listed or CSA approved wire connector to connect
the green/yellow wires together.
9. Tighten the UL listed or CSA approved strain relief.
Electrical Connection Range Hood
10. Repeat all steps above to make the electrical connection in
the range hood terminal box.
11. Connect power supply wires together using the “Make
Electrical Connections” section in the range hood manual.
12. Reinstall the terminal box cover on the In-Line Smart Kit and
reinstall the electrical box cover on the range hood.
13. Reconnect power.
A. Distance between in-line smart kit
and the range hood terminal box
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.