Installation Instructions
Table Of Contents
- Table of Contents
- Table des matières
- Range Hood Safety
- installation requirements
- Installation Instructions
- Prepare Location
- Prepare In-Line Smart Kit
- Install In-Line Smart Kit KVWB40DS Series Range Hoods
- Complete Installation
- Make Electrical Connection
- Install In-Line Smart Kit KVUB60DS Series Range Hoods
- Complete Installation
- Make Electrical Connection
- Install In-Line Smart Kit JXW85DS, JXI85DS, KVWB60DS, and KVIB60DS Series Range Hoods
- Complete Installation
- Make Electrical Connection
- Install In-Line Smart Kit WVW75UC and WV175UC Series Range Hoods
- Complete Installation
- Make Electrical Connection
- wiring diagram
- sÉcuritÉ de la hotte de cuisiniÈre
- Exigences d’installation
- Instructions d’installation
- Préparation de l’emplacement
- Préparation du ventilateur déporté intelligent
- Installation du ventilateur déporté intelligent Hottes série KVWB40DS
- Achever l’installation
- Raccordement électrique
- Installation du ventilateur déporté intelligent Hottes série KVUB60DS
- Achever l’installation
- Raccordement électrique
- Installation du ventilateur déporté intelligent Hottes série JXW85DS, JXI85DS, KVWB60DS et KVIB60DS
- Achever l’installation
- Raccordement électrique
- Installation du ventilateur déporté intelligent Hottes série WVW75UC et WV175UC
- Achever l’installation
- Raccordement électrique
- schÉma de cÂblage
25
Install In-Line Smart Kit
WVW75UC and WV175UC Series Range Hoods
Remove Blower Motor from Range Hood Housing
1. Disconnect power.
2. Using two or more people, place the range hood on its back.
Be sure to set the range hood on a covered surface.
3.
Open the stainless steel panel. Grasp panel at the left corners
and pull down to disengage the 2 catch pins from the spring
catches. The panel is attached at the right and will rotate down.
4. Remove the metal grease filter by pulling the spring release
handle and then pulling down the filter.
5. Remove the 2 screws securing the insulating retainer to the
blower motor and set them aside.
6. Disconnect the blower motor from the range hood wiring.
Using a flat blade screwdriver, and press down on the top clip
of the 9-pin electrical connector while pressing the bottom
clip. Unplug the blower motor from the 9-pin connector.
7. Using the T20
®
Torx
®
adapter with a long extension, remove
the 4 screws, 4 steel washers and 4 rubber washers that
secure the blower motor to the range hood housing and set
them aside.
8. Using the T10 Torx
®
adapter, remove the 7 screws securing
the plastic electrical box cover to the range hood. Remove
the cover and set it aside.
A. Spring release handle
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WARNING
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
A
A. Blower motor
B. Screws, steel washers, and
rubber washers(4)
A. Plastic electrical box cover
B. Screws (7)
A
B
A
B