Installation Instructions

Table Of Contents
19
5. Disconnect the blower motor from the range hood wiring.
Using a flat blade screwdriver, and press down on the top clip
of the 9-pin electrical connector while pressing the bottom
clip. Unplug the blower motor from the 9-pin connector.
6. Using the T10 Torx
®
adapter, remove the screw that secures
the temperature sensor to the bottom rear panel.
7. Using the T10 Torx
®
adapter, remove the 2 screws from the
bottom of the rear panel. Pull the bottom rear panel towards
the front of the range hood to disengage the spring tabs from
the bottom flange of the rear panel. Set the panel and screws
aside.
8. Using the T20
®
Torx
®
adapter with a long extension, remove
the 4 screws that secure the blower motor to the range hood
housing and set them aside.
9. Push on the blower motor to disengage the 2 spring tabs
from the keyhole slots in the top of the range hood housing.
10. Reinstall the bottom rear panel using the T10 Torx
®
adapter
and the 2 screws previously removed.
11.
Reinstall the temperature sensor to the bottom rear panel using
the T10 Torx
®
adapter and the screw previously removed.
12. Reinstall the filter retainer panel using the T10 Torx
®
adapter
and the screws previously removed.
13. Using the T10 Torx
®
adapter, remove the 7 screws securing
the plastic electrical box cover to the range hood. Remove
the cover and set it aside.
A. Temperature sensor
B. Sensor mounting screw
A. Bottom rear panel mounting screws
B. Bottom rear panel
B
A
A
A
B
A. Range hood housing
B. Blower motor
C. Screws (4)
A. Keyhole slots
A. Plastic electrical box cover
B. Screws (7)
A
B
C
A
A
B