Installation Instructions

Table Of Contents
13
4. Using the T10 Torx
®
adapter, remove the 4 screws from the
blower motor cover plate. Remove the cover plate from the
motor and set it aside.
5.
Disconnect the blower motor from the range hood wiring. Press
the top and bottom clip of the 9-pin electrical connector to
disconnect.
6. Using the T20
®
Torx
®
adapter with a long extension, remove
the 4 screws that secure the blower motor to the range hood
housing and set them aside.
7. Push on the blower motor to disengage the 2 spring tabs
from the keyhole slots in the top of the range hood housing.
8. Remove the blower motor from the range hood housing and
set it aside.
9. Remove the electrical knockout from the top of the range
hood and install 1 - UL listed or CSA approved plastic strain
relief. Run the 9-pin connector and pigtail wires through the
strain relief as shown.
10. Connect the 9-pin connector installed to the 9-pin connector
on the inside of the range hood electrical box.
A. Blower motor cover plate
B. Screws (4)
C. Range hood
A. Blower motor
B. Screws - blower motor mounting (4)
C
B
A
B
A
A. Keyhole slots
A. Range hood (top)
B. 9-pin electrical connector (wires)
C. UL listed or CSA approved plastic
strain relief
D. Electrical knockout
A
A
B
C
D