DISPOSER INSTALLATION INSTRUCTIONS
ELECTRICAL INSTALLATION (115 Volt, 60 Hertz) I INSTRUCTIONS: Follow your electrical code in all details. In older houses with limited circuits, or if it appears the circuit is heavily loaded, run a line directly to the main fuse box. 1. Remove the electrical access cover on the bearing bracket assembly. 2. Install standard connector (not furnished) into threaded opening in bearing bracket assembly. 3. Install an operating control switch where it is easily accessMe, for the owner.
GENERAL INSTRUCTIONS. 1. In old houses, it is generally good practice to clean out the existing drain line from, to sewer before installing the sink DISPOSER. 2. The disposer can be installed in steel, monel, stainless steel or cast iron sinks. with a sink opening of 3-l/2ā to 4ā without sink alteration. 3. Standard l-I/Zā O.D. or 2ā O.D. drain pipe is satisfactory for drain lines. Long horizontal drain lines should be eliminated. Drum traps and grease traps should not be used. 4.
WARNING This disposer must be properly grounded before operating, by connecting the chassis ground terminal to a suitable ground, complying with the National Electric Code and/or local electrical codes. KitchenAid Troy, Form 12664A (4-78) Ohio Division 45374 Printed in U.S.A.