Owner's Manual
10
Make Electrical Connection
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box, and then install a
UL Listed or CSA approved 1/2" (1.3 cm) strain relief.
4. Run home power supply cable through strain relief and into
the terminal box.
5. Use UL Listed wire connectors and connect black wires (C)
together.
6. Use UL Listed wire connectors and connect white wires (E)
together.
7. Connect green (or bare) ground wire from home power
supply to yellow-green ground wire (F) in terminal box using
UL Listed wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Check that all light bulbs are secure in their sockets.
11. Reconnect power.
Optional Power Cord Kit Installations
For optional power cord kit installations, follow the instructions
supplied with the power cord kit. See the “Assistance or
Service” section for information on ordering.
NOTE: Use only with range hood cord connection kits that have
been investigated and found acceptable for use with this model
range hood.
Install Duct Covers
NOTE: Remove the lm from the duct covers.
1. Assemble the upper duct covers together, and then install
the duct covers around the support frame. The larger hole
in the anges of the upper duct cover must be outside the
smaller hole in the mating ange of the other upper duct
cover.
2. Secure the upper duct covers together with two
3.5x6.5mm screws at the top and two 2.9 x 3 mm screws
at the bottom. Install one screw on each side at the top and
bottom of the assembled duct covers.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
C
B
A. Knockout
B. Terminal box
C. Terminal box cover
A
B
C
D
E
F
A. Home power supply cable
B. UL Listed or CSA approved
strain relief
C. Black wires
D. UL Listed wire connectors
E. White wires
F. Green (or bare) and yellow-
green ground wires
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
A
A
B
C
C
A. 3.5 x 6.5 mm screws (2)
B. Assembly holes (larger hole outside of
smaller hole on both sides)
C. 2.9 x 3 mm screws (2)