I(it,h -mlqpam Automatic Ice Maker@ lMode’ KU’s’85S
I’ CHANGING THE BIN DOOR AND LOWER PANEL The storage bin door and lower panel are designed to accept an optional decorative wood panel of your choice. DOOR BIN LOWER PANEL WOOD PANEL DIMENSIONS The wood panel should be no more than V4 inch (6 mm) thick. Cut it to the same size as the production metal panel. See Figure 1. To change the bin door panel: 1. Open the bin door. 2. Remove the two screws on top of the door which hold the handle. 3. Remove the handle. 4. Slide the metal panels out. 5.
GENERAL INFORMATION UNPACK l 2 Either a gravity drain system or a sump Ihe water lo an existing drain. 3 l OPEN BOTTOM FIGURE 1 Lay carton flaps FIGURE 2 Set carton upright See Figure 3. face and with all break four open flaps bottom outward. Lift carton u p and off of machine. 4 Remove outside 5R emove the front grill: take out the screws securing the grill at the bottom and Ilft It free of cabinet 6 Turn all tape and packaging material from the and inside of the cabinet.
FOR THE PLUMBER CONNECT TO WATER CONDENSATE (observe local codes) 1 Use l/o” OD soft copper tubing for the cold 1. When drain connection below the level of the unit is not available a condensate pump may be used to lift the water to an available drain. water SUPPlY. 2P rove ‘d e a convenient manual shut-off valve 2. Install condensate pump on floor behind ice maker with discharge tube to the rear. Run bin drain directly into pump as shown in Figure 5A. tn the water lrne 3 PUMP 3.
. REMOVE SHUNT PLUG IN -CONDENSATE PUMP . SCREWS FIG. 5C FIG. 58 FOR THE ELECTRICIAN ELECTRICAL REQUIREMENTS A 115 Volt, 60 Hz, AC only, 15 Amp fused electrical supply is required (time delay fuse or circuit breaker is recommended). It is recommended that a separate circuit, serving only this appliance, be provided. DO NOT use an extension cord. ELECTRICAL APPLIANCE. GROUND IS REOUIRED 3.
(consult your electrical inspector), a temporary adapter may be plugged into the existing 2-prong wall receptacle to mate wrth the Z&prong power supply cord. See Figure 7. THIS, HOWEVER, IS NOT RE- COMMENDED. HOW IT WORKS If this is done, you must connect the grounding eyelet on the adapter to the wall receptacle cover plate screw and from this same screw, you must connect a separate copper ground wire (No. 4 minimum) to a grounded cold water pipe’. See Figure 7.
UNIT WIRING DIAGRAM THINGS TO REMEMBER 0 This model Water enters only during the defrost cycle. Therefore the first cycle will be completed without water in the system. 0 As the room and water temperatures vary, so will the amount of ice produced. This means that higher operating temperatures will result in reduced ice production. 0 The unit will shut off when ice in the storage bin touches the bin thermostat well and will automatically cycle to keep the bin full.
CUBELET i- CUTTER GRIDS CHECK OPERATION 9.l/2”-1 v h CUBE CUTTER GRID Start the unit by turning the service switch “ON” and opening the line water valve. to If NOTE: Left is “OFF” - Middle is “ON” - Right is “CLEAN.” In “CLEAN” position, only the pump operates. If Check condenser v Water will not enter pump pan until freezing plate gets cold and machine goes into a harvest cycle. v Check for even water flow over freezrng Unit must be level for proper operation.