Installation guide

°
AWARNING
Electrical
Shock
Hazard
Electrically
ground
range.
Failure
to
do
so
can
result
in
death,
fire,
or
electrical
shock.
If
codes
permit
and
a
separate
ground
wire
is
used,
it
is
recommended
that
a
qualified
electrical
installer
determine
that
the
ground
path
is
adequate
and
wire
gauge
are
in
accordance
with
local
codes.
Be
sure
that
the
electrical
connection
and
wire
size
are
adequate
and
in
conformance
with
CSA
Standard
C22.1,
Canadian
Electrical
Code,
Part
1
-
latest
edition,
and
all
local
codes
and
ordinances.
A
copy
of
the
above
code
standards
can
be
obtained
from:
Canadian
Standards
Association
178
Rexdale
Blvd.
Toronto,
ON
M9W
1R3
CANADA
m
Check
with
a
qualified
electrical
installer
if
you
are
not
sure
the
range
is
properly
grounded.
Range
Rating*
Specified
Rating
of
Power
Supply
Cord
Kit
and
Circuit
Protection
Explosion
Hazard
Use
a
new
CSA
International
approved
gas
supply
line.
Install
a
shut-off
valve.
Securely
tighten
all
gas
connections.
If
connected
to
LP,
have
a
qualified
person
make
sure
gas
pressure
does
not
exceed
14"
(36
cm) water
column.
Examples
of
a
qualified
person
include:
licensed
heating
personnel,
authorized
gas
company
personnel,
and
authorized
service
personnel.
Failure
to
do
so
can
result
in
death,
explosion,
or
fire.
Observe
all
governing
codes
and
ordinances.
IMPORTANT:
This
installation
must
conform
with
all
local
codes
and
ordinances.
In
the
absence
of
local
codes,
installation
must
conform
with
American
National
Standard,
National
Fuel
Gas
Code
ANSI
2223.1
-
latest
edition
or
CAN/CGA
B149
-
latest
edition.
IMPORTANT:
Leak
testing
of
the
range
must
be
conducted
according
to
the
manufacturer’s
instructions.
120/240
Volts
120/208
Volts
Amps
8.8
-
16.5
KW
7.8
-
12.5
KW
40
or
50
16.6
-
22.5
KW
12.6-185KW
50
*The
NEC
calculated
load
is
less
than
the
total
connected
load
listed
on
the
model/serial/rating
plate.
™If
connecting
to
a
50-amp
circuit,
use
a
50-amp
rated
cord
with
kit.
For
50-amp
rated
cord
kits,
use
kits
that
specify
use
with
a
nominal
1%8"
(34.9
mm)
diameter
connection
opening.
A
time-delay
fuse
or
circuit
breaker
is
recommended.
This
range
is
equipped
with
a
CSA
International
Certified
Power
Cord
intended
to
be
plugged
into
a
standard
14-50R
wall
receptacle.
Be
sure
the
wall
receptacle
is
within
reach
of
range’s
final
location.
O
UU
U
m
Do
not
use
an
extension
cord.
Type
of
Gas
Natural
gas:
This
range
is
design-certified
by
CSA
International
for
use
with
Natural
gas
or,
after
proper
conversion,
for
use
with
LP
gas.
mg
This
range
is
factory
set
for
use
with
Natural
gas.
See
“Gas
Conversions”
section.
The
model/serial
rating
plate
located
behind
the
storage
drawer
on
the
right-hand
side
oven door
frame
has
information
on
the
types
of
gas
that
can
be
used.
If
the
types
of
gas
listed
do
not
include
the
type
of
gas
available,
check
with
the
local
gas
supplier.
LP
gas
conversion:
Conversion
must
be
done
by
a
qualified
service
technician.
No
attempt
shall
be
made
to
convert
the
appliance
from
the
gas
specified
on
the
model/serial
rating
plate
for
use
with
a
different
gas
without
consulting
the
serving
gas
supplier.
See
“Gas
Conversions”
section.
Gas
Supply
Line
m
Provide
a
gas
supply
line
of
34"
(1.9
cm)
rigid
pipe
to
the
range
location.
A
smaller
size
pipe
on
longer
runs
may
result
in
insufficient
gas
supply.
With
LP
gas,
piping
or
tubing
size
can
be
¥2"
(1.3
cm)
minimum.
Usually, LP
gas
suppliers
determine
the
size
and
materials
used
in
the
system.
NOTE:
Pipe-joint
compounds
that
resist
the
action
of
LP
gas
must
be
used.
Do
not
use
TEFLON*
tape.
T®TEFLON
is
a
registered
trademark
of
E.I.
Du
Pont De
Nemours
and
Company.