Installation guide
m
Feed
the
flexible
conduit
behind
the
black
horizontal
cross
brace
and
through
the
strain
relief,
allowing
enough
slack
to
easily
attach
the
wiring
to
the
terminal
block.
Style
1:
Power
supply
cord
strain
relief
m
Remove
the
knockout
at
the
bottom
of
the
terminal
box
for
the
40-amp
supply
cord.
m
Assemble
a
UL
listed
strain
relief
in
the
opening.
A.
Black
horizontal cross
brace
B.
Flexible
conduit
gm
Tighten
strain
relief
screw
against
the
flexible
conduit.
A.
UL
listed
strain
relief
m
Feed
the
power
supply
cord
behind
the
black
horizontal
\
¥
/
cross
brace
and
through
the
strain
relief,
allowing
enough
slack
to
easily
attach
the
wiring
to
the
terminal
block.
5.
Complete
installation
following
instructions
for
your
type
of
electrical
connection:
4-wire
(recommended)
3-wire
(if
4-wire
is
not
available)
Electrical
Connection
Options
If
your
home
has:
And
you
willbe
Go
to
Section:
connecting
to:
A.
Black
horizontal
cross
brace
4-wire
receptacle
A
UL
listed,
4-wire
connection:
B.
Power
supply
cord
(NEMA
type
14-50R)
=
250-volt
Power
supply
cord
m
=
Tighten
strain
relief
screw
against
the
power
supply
cord.
minimum,
©
40-amp,
range
[]
[|
power
supply
(|
cord
4-wire
direct
A
fused
4-wire
connection:
Style
2:
Direct
wire
strain
relief
SEE
(12.7
cm)
disconnect
or
circuit
breaker
box
Direct
wire
m
Remove
the
knockout
as
needed
for
the
flexible
conduit
3-wire
receptacle
A
UL
listed,
3-wire
connection:
connection.
(NEMA
type
10-50R)
=
250-volt
Power
supply
cord
minimum,
m
Assemble
a
UL
listed
conduit
connector
in
the
opening.
40-amp,
range
power
supply
cord
3-wire
direct
I"
(1.0
cm),
A
fused
disconnect
or
circuit
breaker
box
3-wire
connection:
Direct
wire
A.
Removable
retaining
nut
B.
UL
listed
strain
relief
13