Installation guide

Bare
Wire
Torque
Specifications
Attaching
terminal
lugs
to
the
terminal
block
-
20
Ibs-in.
(2.3
N-m)
Wire
Awg
Torque
8
gauge
copper
25
lbs-in.
(2.8
N-m)
6
gauge
aluminum
35
lbs-in.
(4.0
N-m)
5.
Use
a
hex
or
Phillips
screwdriver
to
connect
the
bare
(green)
ground
wire
to
the
range
with
the
ground-link
screw
and
ground-link
section.
The
ground
wire
must
be
attached
first
and
must
not
contact
any
other
terminal.
6.
Use
%"
nut
driver
to
connect
the
neutral
(white)
wire
to
the
center
terminal
block
post
with
one
of
the
10-32
hex
nuts.
ssienas
+}
SS
ss
sus
A
°
a
A.
10-32
hex
nut
B.
Line
2
(red)
C.
Bare
(green)
ground
wire
D.
Ground-link
screw
E.
Neutral
(white)
wire
F.
Line
7
(black)
G.
Terminal
lug
7.
Connect
line
2
(red)
and
line
1
(black)
wires
to
the
outer
terminal
block
posts
with
10-32
hex
nuts.
Securely
tighten
hex
nuts.
9.
Replace
terminal
block
access
cover.
9
3-wire
connection:
Direct
Wire
Use
this
method
only
if
local
codes
permit
connecting
ground
conductor
to
neutral
supply
wire.
1.
Pull
the
wires
through
the
conduit
on
cord/conduit
plate
on
bottom
of
range.
Allow
enough
slack
to
easily
attach
the
wiring
to
the
terminal
block.
A.
Terminal
block
B.
Ground-link
screw
C.
Cord/conduit
plate
D.
Line
2
(red)
wire
E.
Bare
(green)
ground
wire
F.
Line
1
(black)
wire
G.
Metal
ground
strap
16
2.
Attach
terminal
lugs
to
line
2
(red),
bare
(green)
ground,
and
line
1
(black)
wires.
Loosen
(do
not
remove)
the
setscrew
on
the front
of
the
terminal
lug
and
insert
exposed
wire
end
through
bottom
of
terminal
lugs.
Securely
tighten
setscrew
to
torque
as
shown
in
the
following
Bare
Wire
Torque
Specifications
chart.
A.
Terminal
lug
B.
Setscrew
C.
Line
2
(red)
wire
D.
Bare
(green)
ground
wire
E,
Line
1
(black)
wire
Bare
Wire
Torque
Specifications
Attaching
terminal
lugs
to
the
terminal
block
-
20
Ibs-in.
(2.3
N-m)
Wire
Awg
Torque
8
gauge
copper
25
Ibs-in.
(2.8
N-m)
6
gauge
aluminum
35
Ibs-in.
(4.0
N-m)
3.
Use
%"
nut
driver
to
connect
the
bare
(green)
ground
wire
to
the
center
terminal
block
post
with
one
of
the
10-32
hex
nuts.
CO)
rennin
A.
10-32
hex
nut
B.
Line
2
(red)
C.
Ground-link
screw
D.
Bare
(green)
ground
wire
E.
Line
7
(black)
F.
Terminal
lug
4.
Connect
line
2
(red)
and
line
1
(black)
wires
to
the
outer
terminal
block posts
with
10-32
hex
nuts.
5.
Securely
tighten
hex
nuts.
6.
Replace
terminal
block
access
cover.