Installation guide
Remove
the
warming
or
storage
drawer
to
gain
access
to
the
lower
section
of
the
range.
This
will
be
necessary
for
some
of
the
following
installation
steps.
To
Remove
Warming
Drawer:
1.
Open
drawer
to
its
fully
open
position.
2.
Locate
the
black
loops
on
both
sides
of
the
drawer.
Drawer
3.
Pull both
loops
forward
at
the
same
time,
then
pull
drawer
out
another
inch.
Holding
the
drawer
by
its
sides,
not
its
front,
gently
pull
it
all
the
way
out.
“
od
,
et
Power
Supply
Cord
Direct
Wire
Xe
Xe
Electrical
Shock
Hazard
Disconnect
power
before
servicing.
Use
a
new
40
amp
power
supply
cord.
Plug
into
a
grounded
outlet.
Failure
to
follow
these
instructions
can
result
in
death,
fire,
or
electrical
shock.
Electrical
Shock
Hazard
Disconnect
power
before
servicing.
Use
8
gauge
copper
or
6
gauge
aluminum
wire.
Electrically
ground
range.
Failure
to
follow
these
instructions
can
result
in
death,
fire,
or
electrical
shock.
1.
Disconnect
power.
2.
Remove
the
terminal
block
cover
screws
located
on
the
back
of
the
range.
Pull
cover
down
and
toward
you
to
remove
cover.
A.
Hold-down
screws
B.
Terminal
block
cover
12
3.
Remove
plastic
tag
holding
three
10-32
hex
nuts
from
the
middle
post
of
the
terminal
block.
4.
Add
strain
relief.