Specification
12
Make Gas Connection
1. Apply pipe-joint compound made for use with Natural
and Propane gas to the smaller thread ends of the flexible
connector adapters (see C and G in the following illustration).
2. Attach one adapter to the gas pressure regulator and
the other adapter to the gas shut-off valve. Tighten both
adapters, being certain not to move or turn the gas pressure
regulator.
3. Use a
15
/
16
" (24 mm) combination wrench and channel lock
pliers to attach the flexible connector to the adapters. Check
that connector is not kinked.
Typical flexible connection
Complete Connection
1. Open the manual shut-off valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
2. Test all connections by brushing on an approved
noncorrosive leak-detection solution. If bubbles appear,
a leak is indicated. Correct any leak found.
3. Remove surface burner caps and grates from packaging.
Place burner caps on burner bases. Burner caps should
be level when properly positioned. If burner caps are not
properly positioned, surface burners will not light. Place
burner grates over burners and caps.
30" (76.2 cm) models
36" (91.4 cm) models
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make
sure gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
A
B
C
D
E
F
G
H
I
A. Manifold entrance
B. Gas pressure regulator
C. Use pipe-joint compound.
D. Adapter (must have ½" (13 mm) male
pipe thread)
E. Flexible connector
F. Adapter
G. Use pipe-joint compound.
H. Manual gas shut-off valve
I.
1
/
2
" (13 mm) or
3
/
4
" (19 mm) gas pipe
B
A
A. Closed valve
B. Open valve
A
C
B
D
A. Small (AUX)
B. Extra large (UR)
C. Extra large (UR)
D. Medium (SR)
A
C
B
E
D
A. Small (AUX)
B. Medium (SR)
C. Large (R)
D. Extra large (UR)
E. Extra large (UR)