Owner's Manual
Table Of Contents
- COOKTOP SAFETY
- Cooktop Safety
- COOKTOP MAINTENANCE AND CARE
- General Cleaning
- INSTALLATION INSTRUCTIONS
- REQUIREMENTS
- Tools and Parts
- Location Requirements
- Venting Requirements
- Venting Methods
- Electrical Requirements
- Gas Supply Requirements
- INSTALLATION
- Prepare Cooktop
- Install Cooktop
- Make Gas Connection
- Attach Cooktop to Countertop
- Electronic Ignition System
- Complete Installation
- SÉCURITÉ DE LA TABLE DE CUISSON
- Sécurité de la table de cuisson
- ENTRETIEN ET RÉPARATION DE LA TABLE DE CUISSON
- Nettoyage général
- INSTRUCTIONS D’INSTALLATION
- EXIGENCE
- Outils et pièces
- Exigences d'emplacement
- Exigences concernant l'évacuation
- Méthodes d'évacuation
- Spécifications électriques
- Spécifications de l’alimentation en gaz
- INSTALLATION
- Préparation de la table de cuisson
- Installation de la table de cuisson
- Raccordement au gaz
- Fixer la table de cuisson la le comptoir
- Système d’allumage électronique
- Achever l’installation
14
Make Gas Connection
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make
sure gas pressure does not exceed 14ʺ (36 cm) water
column.
Examples of a qualified person include: licensed heating
personnel, authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
1. Apply pipe-joint compound made for use with Natural and
Propane gas to the smaller thread ends of the flexible
connector adapters (see C and G in the following illustration).
2. Attach one adapter to the gas pressure regulator and the
other adapter to the gas shut-off valve. Tighten both adapters,
being certain not to move or turn the gas pressure regulator.
3. Use a 15/16" (24 mm) combination wrench and channel lock
pliers to attach the flexible connector to the adapters. Check
that connector is not kinked.
Typical flexible connection
A. Manifold entrance
B. Gas pressure regulator
C. Use pipe-joint compound.
D. Adapter (must have 1/2" (13 mm) male
pipe thread)
E. Flexible connector
F. Adapter
G. Use pipe-joint compound.
H. Manual gas shutoff valve
I. 1/2" (13 mm) or 3/4" (19 mm) gas pipe
Complete Connection
1. Open the manual shut-off valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
A. Closed valve
B. Open valve
2. Test all connections by brushing on an approved noncorrosive
leak-detection solution. If bubbles appear, a leak is indicated.
Correct any leak found.
3. Remove surface burner caps and grates from packaging.
Place burner caps on burner bases. Burner caps should be
level when properly positioned. If burner caps are not properly
positioned, surface burners will not light. Place burner grates
over burners and caps.
30" (76.2 cm) models
A. Small (AUX)
B. Extra Large (Stack)
C. Large (UR)
D. Medium (SR)
36" (91.4 cm) models
A. Small (AUX)
B. Medium (SR)
C. Large (UR)
D. Extra Large (Stack)
E. Extra Large (Stack)