Manual

The gas supply line shall be equipped with an approved shutoff
valve. This valve should be located in the same area as the
Power TM burner and should be in a location that allows ease of
opening and closing. Do not block access to the shutoff valve.
The valve is for turning on or shutting off gas to the Power TM
burner.
A
B
A. Gas supply line
B. Shutoff valve "open" position
C. To Power TM burner
Natural Gas Conversion
Conversion must be made by a qualified gas technician. The
qualified Natural gas technician shall provide the Natural gas
supply to the selected Power TM burner location in accordance
with the National Fuel Gas Code ANSI Z223.1/NFPA 54 - latest
edition, and local codes. For conversion to Natural gas, the
Natural gas conversion kit supplied with the Power TM burner
must be used.
IMPORTANT: The gas installation must conform with local
codes, or in the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54 - latest edition.
To convert to Natural gas, the Natural Gas Conversion Kit
supplied with the Power TM burner must be used. Follow
instructions for converting to Natural gas in the "Gas
Conversions" section.
_:::::::::::::::::::::) _ ,
C
A. New CSA International approved
"outdoor" flexible gas supply fine
B. Rear of Power TM burner
C. To Natural gas supply
The gas supply line shall be equipped with an approved shutoff
valve. This valve should be located in the same area as the
Power TM burner and should be in a location that allows ease of
opening and closing. Do not block access to the shutoff valve.
The valve is for turning on or shutting off gas to the Power TM
burner.
B
A. Gas supply line
B. Shutoff valve "open" position
C. To Power TM burner
INSTALLATION INSTRUCTIONS
Excessive Weight Hazard
Use two or more people to move and install side
burner.
Failure to do so can result in back or other injury.
1. Position the tank tray for 20 Ib LP gas fuel tank in the island
cabinet.
Unpack Power TM burner. Remove all packaging materials and
remove Power TM burner from carton.
Place Power TM burner into outdoor enclosure, but leave
enough room in back to connect to gas supply and electrical
single prong plug-in.
centerline of
tank tray
20%"
(52.4 crn)
18%"
21/4 It
(5.7 crn)
B
A. 8%2" (20.6 cm)
B. 16_" (41.1 cm)
11