Installation guide

Minimum Cutout Dimensions
NOTES:
Depth dimension may be 213/4'' (55.2 cm) with non-flush
receptacle only if the receptacle is located in upper right or
upper left corner. See "Cutout Top View."
Lower front corners of cutout must be right angles.
17%"
(44.8 cm)
*With flush receptacle, or with non-flush receptacle located in
upper right or upper left corner of cutout.
**With non-flush receptacle.
DIM. 24" (61.0 CM) 27" (68.6 CM) 30" (76.2 CM)
INSTALLATION INSTALLATION INSTALLATION
Width 221/4'' (56.5 cm) 253/4'' (65.4 cm) 283/4'' (73.0 cm)
_+3/16" (4.8 mm) _+3/16" (4.8 mm) _+3/16" (4.8 mm)
Height 17%" (44.8 cm) for all installations
Depth 213/4"(55.2 cm) with flush receptacle, or with non-flush
receptacle located in far corner;
261/4'' (66.7 cm) with non-flush receptacle
Cutout Top View
A C
A. Microwave oven
B. Non-flush receptacle
C. Flush receptacle
D. Non-flush receptacle located in upper
right or upper left corner
18"
(45.7 cm)*
*Measurements include front facing of microwave oven. Depth
measurement also includes door handle.