Performance Data Sheet
2
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F (17.2°C).
� For installation, operation, and maintenance instructions please
refer to the Owner’s Manual.
� It is essential that operational, maintenance, and filter replacement
requirements be carried out for the product to perform as
advertised.
� Model WF-L200V: The filter monitor system measures the amount
of water that passes through the filter and alerts you to replace the
filter. When 90% of the filter’s rated life is used, the filter indicator
light changes from green to yellow. When 100% of the filter’s rated
life is used, the filter indicator light changes from yellow to red, and
it is recommended that you replace the filter. Use replacement
cartridge EDR6D1B-L200V. 2015 suggested retail price of $49.99 U.
S.A./$49.99 Canada. Prices are subject to change without notice.
Model WF-NL120V: Change the water filter cartridge every 6
months. Use replacement cartridge EDR6D1B-N120V.
� The product is for cold water use only.
� Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system.
� For installation, operation and maintenance instructions please
refer Owner's Manual.
Consumer Support 1.800.442.9991
By Whirlpool Corporation
2000 North M63
Benton Harbor, MI 49022
Made in Taiwan.
� Refer to the front cover or “Accessories” section for the
Manufacturer’s name, address and telephone number.
� Refer to the “Warranty” section (in the User Instructions or User
Guide)for the Manufacturer’s limited warranty.
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
Potable City or Well
30 psi - 120 psi (207 kPa - 827
kPa)
33°F - 100°F (0.6°C - 37.8° C)
0.5 GPM (1.89 L/min.) @ 60 psi.
(413.7 kPa)
� Your water filtration system will withstand up to 120 pounds per
square inch (psi) water pressure. If your water supply is higher
than 80 psi, install a pressure reducing valve before installing the
water filtration system.
*Class I particle size: ≥0.5 to < 1.0 μm
**Test requirement is at least 10,000 particles/mL of AC Fine Test Dust.
***These contaminants are not necessarily in your water supply.
Performance may vary based on local water conditions.
®
NSF is a registered trademark of NSF International.