Technical Specs
Table Of Contents
PROGRAMMING
Group Title Description
General Initial set-up
On power-up, blue & red LEDs will flash simultaneously, and the lock will
be in an unlocked state.
Initialise for
private use
1. Touch a MIFARE card to the lock (this becomes the Master User
Card)
2. A double LED flash will confirm acceptance
3. Wait 5 seconds - lock will enter private use
Initialise for
public use
1. Touch a MIFARE card to the lock
2. A double LED flash will confirm acceptance
3. Touch a second MIFARE card to the lock within 5 seconds - this
card becomes the Technician User Card
4. By repeating stage 3 up to 10 times will allow you to add up to 10
Technician User Cards
5. Once complete, wait 5 seconds and the lock will enter public use
Change
operation
function
Perform factory reset
or with the optional Codelocks Keypad Accessory Unit:
1. Plug the Codelocks Keypad Accessory Unit into the lock
2. Touch Master User Card to lock
3. On the keypad, enter:
1. Public Use: press # • 24 • 24 ••
2. Private Use: press # • 26 • 26 ••