Following run time is an estimate based on using a 12V-120AH battery bank for reference. Actual
run time may vary.
Load Consumption Estimate Run time
Cordless Phone 5W 150 hrs
Clock/Radio 8W 100 hrs
Table Lamp 40W/60W 27 hrs/ 18 hrs
Freezer (8.8 cu. ft.) 80W 15 hrs
20” LCD TV 100W 11.5 hrs
Sump Pump (1/2 hp) 350W Not applicable (surge too high)
5. TROUBLESHOOTING
To trouble shoot the unit, please note the error code display on the main unit and review the
“Understanding the Error Codes” in section 4.
Problem Symptom Solution
No AC output and
‘Power’ indicator is
off.
The unit is off Turn unit ON using the toggle switch
No power to inverter Check fuse or the Disconnect switch (if
installed) is either blown or turn OFF
No AC output. ‘Fault’
indicator is ON
Unit detect fault and has
shutdown
Verify the error condition and make
correction and reset unit
Products connected
to unit malfunction or
overheat
Products connected to unit
do not accept modified
sine wave output
Products are not compatible with the
modified sine wave output generated by
the KISAE Power Inverter. See “AC
Load on Power Inverter” in Section 4