Product Manual


Page 12
>25Aac and <27Aac 10 Adc >21Aac and <26Aac 15 Adc
>20Aac and <25Aac 20 Adc >16Aac and <21Aac 35 Adc
<20Aac 40 Adc <16Aac 55 Adc
Manufacturing Default Setting
Fd Reset all settings to manufacturing default settings
(40A for IC121040 or 55A for IC122055, In1, AL1, SdL, Flo, Cb3)
Understanding the Charger De-rating Current:
The charger current will be de-rated when the environment temperature reaches 60
°C (140 °F) or the internal temperature reaches the pre-set values.
Unit De-rated Values
>90°C (194°F) Maximum charger will de-rated
to half
>95°C (203°F) Charger current reduced to 5A
Internal Temperature
<85°C (185°F) Charger current recover back
to set value
>60°C (140°F) Charger current reduced to 5A Environment Temperature
>55°C (131°F) Charger current recover back
to set value
Enter Function Menu for unit setting:
To enter unit Function Menu, press and hold “Power” and “Select” button together for about 5
seconds until a beep is sounded.
When you are in Function Menu:
Press ‘Power’ button for 1 second to toggle between different Functions Menu like ‘Cu’, ‘In’,
‘AL’, ‘Sd’, ‘bAt’, ‘Cb’ and ‘Fd’ etc.
Press ‘Select’ button for 1 second to enter Individual Function Set Menu and you can
make change to the settings.
The unit will EXIT the Main Menu automatically if ‘Power’ and ‘Select’ buttons is not trigger
for more than 5 seconds.
When you are in Individual Function Set Menu:
Press ‘Select’ button for 1 second to toggle between different setting values.
Press ‘Select’ button for 5 seconds to set selected setting and exit to next Main Menu
See more details on flow chart below.