vi) Inverter only with No By-Pass or Battery Charger Function (‘INT’ = ‘ON’, ‘CHG’ = ‘ON or OFF’)
This setting is specially designed so that the AC load connected to AC Output is always getting
clean sinewave power from the inverter. Press and hold the ‘Power button for one second to turn
On or Off the Inverter. As the unit is set to Inverter only, it overrides the Charger On/OFF setting,
meaning the charger is disabled in any condition. When this mode is used, a separate battery
charging source is required to charge the battery.
INT
ON
Inverter Only: (Unit is running as inverter only, No By-Pass and Battery
Charging Function)
CHG
OFF/ON
With Inverter turned on and no AC Input Source or Shore Power is detected.
- Display shows battery voltage (12.8V), use or button to see DC Current
discharged from battery, AC Output Power.
- is on indicates inverter is providing AC Power.
- icon indicates estimated battery capacity.
- Power’ indicator on indicates Inverter function is On.
- If AC Output indicator is On, it indicates AC Output Switch is turned On (AC is
available at the output socket and the output hardwire terminal).
- If AC Outputindicator is Off, it indicates AC Output Switch is turned Off (AC is not
available at the output socket and the output hardwire terminal).
- Press and hold ‘Escape’ button for 5 seconds to toggle AC Output Switch On and Off.
- Status’ indicator is solid amber indicates inverter is running.
Note: The ‘Power’ button can be used to turn Inverter On and Off.
With Inverter turned on with AC Input Source or Shore Power is detected.
With AC Input Source detected, the icon will be shown on the display but there is
no inference to the AC Output. AC Output is still getting the power from the Inverter.
- Display shows battery voltage (12.8V), use or button to see DC Current
discharged from battery, AC Output Power.
- is on indicates AC Input Source is detected.
- is on indicates inverter is providing AC Power.
- icon indicates estimated battery capacity.
- Power’ indicator on indicates Inverter function is On.
- If AC Output indicator is On, it indicates AC Output Switch is turned On (AC is
available at the output socket and the output hardwire terminal).
- If AC Outputindicator is Off, it indicates AC Output Switch is turned Off (AC is not
available at the output socket and the output hardwire terminal).
- Press and hold ‘Escape’ button for 5 seconds to toggle AC Output Switch On and Off.
- Status’ indicator is solid amber indicates inverter is running.
Note: The ‘Power’ button can be used to turn Inverter On and Off.