Product Manual
Page 17
Exploring the Unit Settings
a) Inverter and Charger Functions
i) Automatic Backup with Battery Charger Function Enabled – Unit Default Setting (‘INT’ = ‘ABU’,
‘CHG’ = ‘ON’)
This is the most commonly used setting on the unit. The charger function is enabled and the
Inverter is in standby condition when AC Input Source or Shore Power is available. The Inverter
will automatically turn on when AC Input source or shore power is interrupted. This provides
smooth, uninterrupted AC power to the load.
INT
ABU
Automatic Backup with Battery Charger Function Enabled (Unit Default setting)
CHG
ON
When AC Input Source or Shore Power is available, unit is running in By-Pass Mode. AC Output is
getting the power from the AC Input Source or Shore Power. Charger is enabled and Inverter is in standby
condition.
- Display shows battery voltage (14.2V), use or button to see DC Current charging
the battery, AC Input Power.
- is On indicates AC Input Source is in use.
- is On indicates AC Output is getting the power from AC Input source.
- is On indicates the charger is enabled and is charging the battery.
- icon indicates the charging stage of the battery.
- ‘Power’ indicator on indicates unit is On.
- If ‘AC Output’ indicator is On, it indicates the AC Output Switch is turned On (AC is
available at the output socket and the output hardwire terminal).
- If ‘AC Output’ indicator is Off, it indicates the AC Output Switch is turned Off (AC is
not available at the output socket and the output hardwire terminal).
- Press and hold ‘Escape’ button for 5 seconds to toggle AC Output Switch On and Off.
- If ‘Status’ indicator is solid green, it indicates battery is fully charged.
- If ‘Status’ indicator is flashing green, it indicates battery charging is in progress.
Note: In By-Pass Mode, the ‘Power’ button function is disabled. It cannot be used to
turn Off the unit.
When there is a blackout (AC Input Source or Shore Power is not available), unit is running in
Inverter/Battery Mode. Unit will automatically switch to getting AC Power from the inverter. Charger is
disabled.
- Display shows battery voltage (12.8V), use or button to see DC Current
discharge from battery, AC Output Power.
- is On indicates inverter is providing AC Power.
- icon indicates estimated battery capacity.
- ‘Power’ indicator on indicates unit is On.
- If ‘AC Output’ indicator is On, it indicates AC Output Switch is turned On (AC is
available at the output socket and the output hardwire terminal).
- If ‘AC Output’ indicator is Off, it indicates AC Output Switch is turned Off (AC is not
available at the output socket and the output hardwire terminal).
- Press and hold ‘Escape’ button for 5 seconds to toggle AC Output Switch On and Off.
- If ‘Status’ indicator is solid amber, it indicates inverter is running.
- If ‘Status’ indicator changes to flashing amber, it indicates AC Input Source is
detected and will switch back to By-Pass Mode shortly.
Note: In Inverter/Battery Mode, the ‘Power’ button can be used to temporarily turn the
unit Off to save battery power if AC Output power is not required. When AC Input Source
or Shore Power returns, unit will automatically turn On and run in By-Pass Mode again.