Product Manual
Page 14
6. SPECIFICATIONS
Note: Specifications are subject to change without notices.
Charger Output: AC 1220 / AC 1240 / AC 1260
Output Current (Maximum) 20A / 40A / 60A
Output Voltage Range
Charge 14.2 - 15.5 V
Float 13.4 - 13.8 V
Equalize 16.0 V
Charging Control Three stages (Bulk/Absorption/Float)
Two stages (Bulk/Absorption)
Constant Power Supply (Program setting)
DC Output Bank Three
Selectable Battery Type Gel, AGM, Flooded, Lithium, Program
Parasitic Current < 2 mA
Charger Input:
AC Input Voltage (Nominal) 100, 120, 220, 230, 240 VAC
AC Input Operating Range 90 - 265 VAC
AC Input Frequency Range 47 - 63 Hz
Power Consumption (Full Load) 350W / 700W / 1050W
Power Factor Correction Yes
Charger Efficiency > 82%
Protection and Features:
Reverse Battery Yes, unit shutdown
Over Charge Yes, unit shutdown
Over Temperature Yes, unit de-rated and shutdown
Output Short Circuit Yes, unit shutdown
DC Fuse 2*15A, 32V / 2*30A,32V / 3*30A,32V
Cooling Force air ventilation
Temperature Setting Hot, Normal, Cold (no sensor connected)
Battery Temperature Sensor Port RJ12 (optional battery sensor use)
Digital Display Port RJ12 (optional display panel use)
Display:
LCD Display (with back lighting) Charging status, Battery Voltage
Warning and Fault Code A01-02, E01-09
Digital Display Port RJ12, use with optional display panel
AC Input and DC Output Connection:
AC Input Connection Hardwire or AC Cord
DC Output Connection Heavy Duty Studs (3 banks)
DC Output Ground Single Heavy Duty Common Ground Stud
Environmental and Operating Temperature:
Storage Range -40° to 70° C (-40° to 158° F)
Operating Range -20° to 60° C (-4° to 140° F)
Humidity 5-95%, RH non-condensing
Ingress Protection IP32
Based Unit Weight and Dimensions:
AC 1220 5.3 lb., 11.6 x 8.1 x 3.4 inches
(2.4 Kg, 295 x 206 x 86 mm)
AC 1240 5.7 lb., 11.6 x 8.1 x 3.4 inches
(2.6 Kg, 295 x 206 x 86 mm)