User guide

TM
Model 4900M0247-01
Rev. 5/14 6-17
Lubrication and Maintenance
1. Replace 10-micron spin-on filters on tank annually.
2. Fill system with SAE 10W-20 multigrade wide temperature range transmission hydraulic fluid. Reservoir capacity
is approximately 8 gal (30.2L).
3. Start system and run with tractor at idle and fans turned off for 1-2 minutes. Switch fans to full speed and run with
tractor at idle for 1-2 minutes.
4. Check reservoir fluid level and fill as required. Hydraulic fluid level should be within 1"-2" from top of reservoir after
pump has run and hydraulic hoses have been primed to allow fluid to expand when heated.
NOTICE
Clean and grease PTO shaft coupling with high-pressure industrial coupling grease (Chevron
®
coupling
grease or equivalent) meeting AGMA CG-1 and CG-2 Standards each time driveshaft is installed or premature
wear and equipment failure can occur.
TRACTOR MOUNTED PUMP DRIVE AND OIL COOLER
NOTE: Periodically check and clean oil coolers.
Oil filter
Oil cooler
Oil reservoir