User guide

M0247-01Model 4900
6-32 Rev. 5/14
TM
Lubrication and Maintenance
CAN POWER CABLE
P/N A19396
Signal Wire
Gauge
Color MM SCL F1 RM1 F2 RM2 F3 RM3 TERM
Power 8 Red S - A - A - A - -
Ground 8 Black U - - 3 - 3 - 3 -
Fused Power 1 16 Red/Yellow - - B 4 - - - - -
Fused Power 2 16 Red/Yellow - - - - B 4 - - -
Fused Power 3 16 Red/Yellow - - - - - - B 4 -
CAN H 18 TP Yellow W 1 - 2 - 2 - 2 1
CAN L 18 TP Green V 2 - 5 - 5 - 5 2
RM Enable 1 16 Tan - - B 1 - - - - -
RM Enable 2 16 Orange - - - 6 - 1 - - -
RM Enable 3 16 Blue - - - - - 6 - 1 -
Master Module
(MM)
F1
Fuse
15A
Terminator
(TERM)
Scale (SCL)
Row Module (RM)
Row Module (RM2) Row Module (RM3)
F2
Fuse
15A
F3
Fuse
15A