Instruction Manual Portable ECG Monitor
Thank you for purchasing XYZlife portable ECG monitor. Please read this entire instruction manual. If you are using this device for the very first time, please follow the instructions and use it correctly. Please keep the instruction manual for future reference. XYZlife does not bear legal responsibilities for any casualty or product damage caused by users’misuse.
Table of Contents Caution ...........................................................................................................2 Safety Conditions Product Description and Indication of Use .........................................4 Components and Accessories Procedure of Set-up ....................................................................................7 Initial Set Up XYZlife BC1 Patch Procedure (with Optional Electrode Patch) Battery .........................................................
Caution Safety Conditions This product is designed to monitor ECG (Electrocardiogram) only. Do not use for any other purpose: such as monitoring life signal or emergency. Use for self-diagnosis or self- treatment is dangerous, please always consult your doctor if you notice any change in your condition, regardless of your measurement result. The measurement result is used for monitor purpose only. Do not read it yourself and conduct any treatment without consult from medical professionals.
Caution WARNING! • Do not use the device in ICU or operation room. • Do not use the device in hospital or other medical institutions without the permission of physicians. This product could impact other medical devices. • Do not use the device together with defibrillator (AED). • Avoid flammable materials, anesthetics, drugs or pressurized oxygen (such as in a hyperbaric chamber, ultraviolet sterilizer or oxygen tent). • Do not attempt self-diagnosis or self-treatment based on the measurement results.
Product Description Single lead portable ECG monitor, is addressed as“device”below. The device is used to measure user’ s ECG continuously. Recordings can be transmitted, and viewed by the collaborative App. The device consists of three main components: (1) BC1 main unit. It attaches to user’ s body via electrode patch (optional) , using blue tooth to keep communication with mobile devices.
Product Description Component 1 / Main Unit D E C B A F Main Unit Function A. Power Button Press 1st time to power ON, 2nd time to power OFF B. Battery LED LED light to display current battery life Green light: Full power / Flashing red light: Charging / Red light: Battery hour is less than 6 hours C. Status LED LED light to show system status LED light to display current battery life Green light: Power above 60% Red light: Power less than 20%(low power) Flashing red light: in charging D.
Product Description Component 2 / Carry Bag Easy carry and protection of device Component 3 / Charger USB Connector Model:GS2U-006-050-A Input: 100-240V~0.2A 60/50Hz Output: 5V 1200mA 6W Max Charger is complied with 60601-1 3.
Initial Set Up Initial Set Up 1.Charging Take out BC1 main unit, and use USB cable start charging. 2.Download BC1 App to your mobile device (The device supports Android4.4 or more updated version, as well as iOS7.0 or more updated version.) Please find and download Apps for XYZlife Patch on Google Play or App store). 3.Follow APP instruction to complete initial set up and Bluetooth connection.
Initial Set Up 3. Calling Key -Press the calling key on the front of the main unit to make warning beep sounds. -After 30 seconds, the main unit will send calling texts to preset contact persons. WARNING: Press calling key again to stop mis-trigger (Warning beep sounds will stop) 4.
Battery Battery Life and Charge 1. The product is using Li ion rechargeable battery. 2. Use designated charger to charge the battery. Please charge fully in first time use. 3. Battery LED displays GREEN light when charging is completed. 4. The battery with full power works continuously for 8 hours. 5. Battery can be recharged at 500 times. 6. It takes around 2.5 hours to fully charge the battery. Caution during measurement To obtain correct ECG readings, make sure you wear it correctly.
Care and Maintenance Sound and Flashing Sound Message Note Beep/ 1 short beep 1. Confirm POWER ON/OFF Beep/ 3 long beeps Battery power is less than 60% Beep/ 5 long beep System Error Continuous beeps Calling 2.
Care and Maintenance Troubleshooting Problem Cause Solution Unable power ON Battery is exhausted and voltage is too low Please charge the device, waiting for GREEN light. Device unable to sync with mobile Distance between the device and mobile is too far. Make sure the distance between device and mobile device is within 8meters. Sync APP with device manually Abnormal Bluetooth pairing ECG data is disappeared while using The ECG readings appear upside down, Or unusual readings 1.
Care and Maintenance Storage 1. Do not place any object on the top of the main unit, or strike it. This could damage it. 2. Do not wipe the device or electrode connecting point with benzene, gasoline, paint thinner, concentrated alcohol, or other solvent detergents. 3. Do not disassemble the device. Repairs should only be carried out by authorized personnel. Disassemble and repair are for authorized personnel only. 4.
FCC statement Guidance and manufacturer’ s declaration - electromagnetic Emissions The BC1 ECG monitor is intended for use in the electromagnetic environment specified below. The customer or the user of the BC1 ECG monitor should assure that it is used in such an environment. Emission test Compliance Electromagnetic environment - guidance RF emissions CISPR 11 Group1 The device’ s RF emissions are very low and are not likely to cause any interference in nearby electronic equipment.
FCC Statement Guidance and manufacturer’ s declaration - electromagnetic immunity The BC1 ECG monitor is intended for use in the electromagnetic environment specified below. The customer or the user of the BC1 ECG monitor should assure that it is used in such an environment. Immunity test Conducted RF IEC 61000-4-6 Radiated RF IEC 61000-4-3 IEC 60601 Compliance Test level 3 Vrms 150 kHz to 80 MHz 3V 3 V/m 80 MHz to 2.
This Device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Notice:The changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Specification CE xxxx Theproduct follows EC 93/42/EEC regulation The important message regarding EMC With the increase use of electronic devices, such as personal computer or smart phones, any medical device might have risk of being interfered by electromagnetic from them. Any interference might lead to the medical abnormal function, causing dangerous situations. This medical device should not interfere other devices. EN60601-1-2 regulation has been applied.
Specification Model: BC1 ECG Channel: single channel ECG wave measuring range : 0-2mV( Heart rate range: 25 to 250 BPM ( 0.1mV error) 5BPM) Frequency response : 0.67Hz to 40Hz / Sample rate: 200Hz Ingress Protection Rating: IP22 Protection type and range against electrical shock: TYPE BF ECG electrode is applied Part Battery: Rechargeable Lithium ion battery Operation Temp. : +10℃ to +45℃ Operation Humidity : 30% to 95% Operation atmospheric pressure: 700-1060 mbar Storage Temp.
Symbols Used for Product or Package Symbols Meanings Manufacture: Kinpo Electronics, Inc. Address: 10F, No. 99, Sec5, NanJing E. Rd, Taipei City 105, Taiwan Website: www.xyz-life.com Manufactured in Thailand Manufacturing batch / lot No.
Symbols Used for Product or Package Symbols Meanings The device complies with Federal Communications Commission Recycling Symbol International protecting mark Serial Number of product WARNING and Cautions Please follow the instructions carefully Transportation and storage temp. requirement Transportation and storage humanity requirement Warning symbol denoting a device's susceptibility to electrostatic discharge. Radio frequency fields beyond this point may exceed the FCC, etc.
NOTE
NOTE
NOTE
HDWM4912Z00