user manual

MNM©2009
KTT©2011
Page 28
engine continues to accelerate until idle RPM is reached. Now, the command of the
turbine will be taken over by the transmitter.
Turbine stopping and cooling
The user can finish the sequence at any moment, simply setting the trim to "off"
position. If the engine was on "running" phase (above idle rpm), a cooling sequence
will be triggered, cycling the starter motor until the EGT is below the minimum
programmed temperature. This cooling sequence will be aborted if the trim is raised
again.
If the engine is hot (EGT higher than the minimum temperature) at the moment
that the user triggers the auto start cycle, then the FADEC will begin a cooling cycle
until the temperature is below 100C.
Manual cool down:
In the event if the engine does go into the cool down mode after the turbine shuts
down or flames-out, the user can lower the trim, and advance throttle stick to trigger
cooling from starter. Make sure you simulate the auto cooling sequence and monitor
the real time temperature and do not leave motor running to longer than a couple of
seconds.
Another option is to unplug reconnect power to ECU, this power cycle will enable ECU
to recognize that the engine temperature is still higher than normal, and should
engage auto cool down.
RUN menus
Under this submenu, the parameters used for the engine during normal run can be
modified. Note: Some of these menus parameters cannot be changed by user. It
was factory set for best operation and to protect turbine. Please do not change
these values set by factory. This may void your warranty!
Full power speed: On this screen you can set the RPM that the engine will run at
100% throttle. If the engine manufacturer has set a maximum limit, you will only be
able to reduce the max RPM, (145,000 for the K-80 and 125,000 for the K-170)