Test functions
The FADEC provides testing functions to the starter motor, glow plug, pump and both
solenoid valves. These test screens are only available when the FADEC is on “Trim
Low” status, that is to say, recently powered up and receiving a STOP signal from the
TX. Pressing the (-) button (under the “ON” reading on the screen) will energize the
selected device and pressing (+) will shut down. Special care should be taken when
testing the pump, as it is possible that fuel can be pumped into the engine, flooding it,
and causing a hot start on next startup.