8. FILLING A TANK
The tank should be filled through the inlet using a dispensing nozzle as used
in dispensing units of gas stations (see Section 5).
It is forbidden to fill the tank directly from a tanker. Moreover,
TruckMaster® can be filled only with diesel fuel with a flash
point range of above 140˚F (60˚C) and below 200˚F (93˚C). Liq-
uids outside this specified flash point range are forbidden to be stored and
dispensed from this product. The maximum filling rate is 25 US gal/min and
it should not be exceeded. Pay attention to the vent and check if it is not
blocked when filling a tank.
9. CONNECTING THE PUMP
Before refueling, the pump must be connected to a power source. Depend-
ing on the specifications, TruckMaster® can be equipped with a pump pow-
ered by a 12 V DC and/or 24 V or 110 V AC 60 Hz. The supply voltage of the
pump must be consistent with the voltage stated on the pump nameplate.
Wires of the DC-powered pumps must also be correctly con-
nected, namely, the black wire must be connected to the nega-
tive and the red wire connected to the positive pole.
More information can be found in the pump manual included with the de-
vice.
10. VEHICLE REFUELLING
Before refueling, the vehicle pump must be connected to a power source
(see Section 9). Also, when using TruckMaster® 114, make sure that the ball
shut-off valve before the pump is open. Turn on the pump using the switch
and insert the filling nozzle into the fuel tank inlet. Refueling will start within
two minutes after pressing the nozzle pushbutton.