INSTALLING LP GAS TANK 
Connect LP Gas Tank 
Before connecting, be sure that there is no debris 
caught in the head of the LP gas tank, head of the   
regulator valve or in the head of the burner and   
burner ports. 
Connect regulator/hose assembly to tank by   
turning knob clockwise stops. 
Disconnect LP Gas Tank 
Before disconnecting make sure the LP gas tank   
valve is "CLOSED". 
Disconnect regulator/hose assembly from LP gas   
tank by turning knob counterclockwise until it is loose. 
Caution: LP gas tank must be properly disconnected   
and removed prior to moving this pit. 
Connect NG 
1. A professionally-installed shut-off valve between the supply 
piping and the socket is recommended, but not required, by the   
National Fuel Gas Code. Socket connection must be made outdoors. 
2. Coat the gas supply pipe nipple with gas resistant pipe dope or approved teflon tape. Screw socket onto gas 
supply pipe (house gas source), and wrench-tighten. 
3. Pull back the sleeve on the quick disconnect socket and insert the unattached end of the gas hose into the 
socket. Release the sleeve and continue pushing the hose into the socket until the sleeve snaps into the locked 
position. 
4. When the quick disconnect socket and the gas hose are connected, a valve in the socket opens automatically 
to permit full gas flow. When the gas hose is disconnected, the valve in the socket instantly and positively shuts 
off the flow of gas, the grill can be disconnected from the gas source by disconnecting the gas hose from the 
quick disconnect socket. The socket should be left attached to the gas source (hose piping). 
Disconnect NG 
With proper assembly, the gas hose cannot be removed without pushing the quick disconnect sleeve back. To 
disconnect, push sleeve back and pull plug out of sleeve (this automatically shuts off gas). 
The appliance and its individual shut off valve must be disconnected from the gas supply piping system during 
any pressure testing on that system at test pressures in excess of 1/2 psi(3.5kPa). 
The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve 
during any pressure testing of the gas supply piping system at test pressures equal to or less than1/2psi(3.5kPa). 
This appliance can use two fuel gas: LPG-Propane OR Natural Gas 
Suitable LP gas tank size for this appliance is 20IB(9.1KG) 
Do not fill the LP gas tank with more than 80% liquid gas 
The in let gas supply pressure for the purpose of input adjustment pressure: 
LPG-Propane 11”  in w.c.(2.74kPa) 
Natural Gas 7”  in w.c.(1.74kPa) 
The appliance must be isolated from the gas supply piping system by closing its individual 
manual shutoff valve during any pressure testing of the gas supply piping system at test 
pressures equal to or less than 1/2psi (3.5kPa) 
The LP-gas supply cylinder to be used must be: constructed and marked I accordance with the 
U.S. Department of Transportation (D.O.T.) Specifications for LP-Gas Cylinders. Provided with a 
listed overfilling prevention device, and provided with a cylinder connection device compatible 
with the connection for the appliance. 
WARNING: Make sure LP gas tank valve is closed.   
Close by turning valve clockwise. 
Place the LP gas tank upright into the tank tray and secure the tank by screw. 
LP GAS 
NG 