proper register setup.
Figure 5: X-axis Click Event Trigger Example
Y-axis Click Flag
YCLP (0Dh:bit3) and YCLN (0Dh:bit2) are Y-axis positive and negative direction click flag. They
work in analog to XCLP and XCLN.
Z -axis Click Flag
ZCLP (0Dh:bit1) and ZCLN (0Dh:bit0) are Z-axis positive and negative direction click flag. They
work in analog to XCLP and XCLN.