User Manual
VS1003
4 CHARACTERISTICS & SPECIFICATIONS
4 Characteristics & Specifications
4.1 Absolute Maximum Ratings
Parameter Symbol Min Max Unit
Analog Positive Supply AVDD -0.3 2.85 V
Digital Positive Supply CVDD -0.3 2.85 V
I/O Positive Supply IOVDD -0.3 3.6 V
Current at Any Digital Output ±50 mA
Voltage at Any Digital Input -0.3 IOVDD+0.3
1
V
Operating Temperature -40 +85
◦
C
Storage Temperature -65 +150
◦
C
1
Must not exceed 3.6 V
4.2 Recommended Operating Conditions
Parameter Symbol Min Typ Max Unit
Ambient Operating Temperature -40 +85
◦
C
Analog and Digital Ground
1
AGND DGND 0.0 V
Positive Analog AVDD 2.6 2.8 2.85 V
Positive Digital CVDD 2.4 2.5 2.85 V
I/O Voltage IOVDD CVDD-0.6V 2.8 3.6 V
Input Clock Frequency
2
XTALI 12 12.288 13 MHz
Internal Clock Frequency CLKI 12 36.864 52.0
4
MHz
Internal Clock Multiplier
3
1.0× 3.0× 4.5×
4
Master Clock Duty Cycle 40 50 60 %
1
Must be connected together as close the device as possible for latch-up immunity.
2
The maximum sample rate that can be played with correct speed is XTALI/256.
Thus, XTALI must be at least 12.288 MHz to be able to play 48 kHz at correct speed.
3
Reset value is 1.0×. Recommended SC_MULT=3.0×, SC_ADD=1.0× (SCI_CLOCKF=0x9000).
4
52.0 MHz is the maximum clock for the full CVDD range.
(4.0 × 12.288 MHz=49.152 MHz or 4.0 × 13.0 MHz=52.0 MHz)
Version: 1.08, 2014-12-19 7