Datasheet
© 2018 Kingbright. All Rights Reserved. Spec No: DSAK7854 / 1203011475 Rev No: V.9B Date: 03/22/2018
Page 2 / 4
ABSOLUTE MAXIMUM RATINGS at T
A
=25°C
ELECTRICAL / OPTICAL CHARACTERISTICS at T
A
=25°C
KPHB-1608CGKSYKC-GX
Parameter Symbol Emitting Color
Value
Unit
Typ. Max.
Wavelength at Peak Emission I
F
= 20mA λ
peak
Green
Super Bright Yellow
574
590
- nm
Dominant Wavelength I
F
= 20mA λ
dom
[1]
Green
Super Bright Yellow
570
590
- nm
Spectral Bandwidth at 50% Φ REL MAX
I
F
= 20mA
Δλ
Green
Super Bright Yellow
20
20
- nm
Capacitance C
Green
Super Bright Yellow
15
20
- pF
Forward Voltage I
F
= 20mA V
F
[2]
Green
Super Bright Yellow
2.1
2.0
2.5
2.5
V
Reverse Current (V
R
= 5V) I
R
Green
Super Bright Yellow
-
10
10
uA
Temperature Coefficient of λ
peak
I
F
= 20mA, -10°C ≤ T ≤ 85°C
TC
λpeak
Green
Super Bright Yellow
0.12
0.12
- nm/°C
Temperature Coefficient of λ
dom
I
F
= 20mA, -10°C ≤ T ≤ 85°C
TC
λdom
Green
Super Bright Yellow
0.07
0.08
- nm/°C
Temperature Coefficient of V
F
I
F
= 20mA, -10°C ≤ T ≤ 85°C
TC
V
Green
Super Bright Yellow
-1.9
-1.9
- mV/°C
Notes:
1. The dominant wavelength (λd) above is the setup value of the sorting machine. (Tolerance λd : ±1nm. )
2. Forward voltage: ±0.1V.
3. Wavelength value is traceable to CIE127-2007 standards.
4. Excess driving current and / or operating temperature higher than recommended conditions may result in severe light degradation or premature failure.
Parameter Symbol
Value
Unit
Green Super Bright Yellow
Power Dissipation P
D
75 mW
Reverse Voltage V
R
5 5 V
Junction Temperature T
j
115 115 °C
Operating Temperature T
op
-40 to +85 °C
Storage Temperature T
stg
°C
DC Forward Current I
F
30 30 mA
Peak Forward Current I
FM
[1]
150 175 mA
Electrostatic Discharge Threshold (HBM)
-
3000 3000 V
Thermal Resistance (Junction / Ambient) R
th
JA
[2]
380 590 °C/W
Thermal Resistance (Junction / Solder point) R
th
JS
[2]
265 505 °C/W
-40 to +85
75
Notes:
1. 1/10 Duty Cycle, 0.1ms Pulse Width.
2. R
th
JA
,R
th
JS
Results from mounting on PC board FR4 (pad size ≥ 16 mm
2
per pad).
3. Relative humidity levels maintained between 40% and 60% in production area are recommended to avoid the build-up of static electricity – Ref JEDEC/JESD625-A and JEDEC/J-STD-033.
Kingbright