ABSOLUTE MAXIMUM RATINGS at T
A
=25°C
ELECTRICAL / OPTICAL CHARACTERISTICS at T
A
=25°C
Parameter Symbol Emitting Color
Value
Unit
Typ. Max.
Wavelength at Peak Emission I
F
= 20mA λ
peak
Blue
Green
Hyper Red
465
520
631
- nm
Dominant Wavelength I
F
= 20mA λ
dom
[1]
Blue
Green
Hyper Red
470
525
624
- nm
Spectral Bandwidth at 50% Φ REL MAX
I
F
= 20mA
Δλ
Blue
Green
Hyper Red
22
35
20
- nm
Capacitance C
Blue
Green
Hyper Red
100
100
25
- pF
Forward Voltage I
F
= 20mA V
F
[2]
Blue
Green
Hyper Red
3.3
3.2
2.1
4.0
4.0
2.5
V
Reverse Current (V
R
= 5V) I
R
Blue
Green
Hyper Red
-
50
50
10
uA
Temperature Coefficient of λ
peak
I
F
= 20mA, -10°C T 85°C
TC
λpeak
Blue
Green
Hyper Red
0.04
0.05
0.13
- nm/°C
Temperature Coefficient of λ
dom
I
F
= 20mA, -10°C T 85°C
TC
λdom
Blue
Green
Hyper Red
0.03
0.03
0.06
- nm/°C
Temperature Coefficient of V
F
I
F
= 20mA, -10°C T 85°C
TC
V
Blue
Green
Hyper Red
-3.0
-3.0
-1.9
- mV/°C
Parameter Symbol
Value
Unit
Blue Green
Hyper Red
Power Dissipation P
D
mW
Reverse Voltage V
R
5 5 5 V
Junction Temperature T
j
115 115 125 °C
Operating Temperature T
op
-40 to +85 °C
Storage Temperature T
stg
-40 to +85 °C
DC Forward Current I
F
30 30 70 mA
Peak Forward Current I
FM
[1]
100 100 200 mA
Electrostatic Discharge Threshold (HBM)
-
250 450 3000 V
Thermal Resistance (Junction / Ambient) R
th
JA
[2]
285 270 200 °C/W
Thermal Resistance (Junction / Solder point) R
th
JS
[3]
200 190 115 °C/W
120 120
175
Notes:
1. The dominant wavelength (λd) above is the setup value of the sorting machine. (Tolerance λd: ±1nm. )
2. Forward voltage: ±0.1V.
3. Wavelength value is traceable to CIE127-2007 standards.
4. Excess driving current and / or operating temperature higher than recommended conditions may result in severe light degradation or premature failure.
Notes:
1. 1/10 Duty Cycle , 0.1ms Pulse Width .
2. R
th
JA,
R
th
JS
Results from mounting on PC board FR4 (pad size16 mm
2
per pad).
3. Relative humidity levels maintained between 40% and 60% in production area are recommended to avoid the build-up of static electricity – Ref JEDEC/JESD625-A and JEDEC/J-STD-033.
KAAF-3529BGRS-132
Kingbright