Before proceeding to the connection of the
oven make sure that:
- the  limiting  valve  and  the  domestic
electrical circuit are sufficient to support
the load  of the  appliance (see
identification plate);
- the electrical system is equipped  with
an  earthing  cable  in  accordance  with
current norms and legal provisions;
- the plug or omnipolar switch used to carry
out the connection is easily accessible
once the appliance is installed.
The appliance is sold with power cable, the
conductors of which have a minimum section
of 3x1.5 mm. Besides this, the cable must
have  a  normalised  plug  suitable  for  the
electrical load indicated on the identification
plate.
The plug should be connected to a suitable
elctrical socket.
If a direct connection to the supply is desired
an  omnipolar  switch  having  a  minimum
opening of 3mm between the contacts must
be installed between the appliance and the
electricity  supply;  this  switch  must  be
suitable  for  the  electrical  load  of  the
appliance and must conform to the current
norms.
The yellow/green earth  wire must not  be
interrupted by the switch.
In  every  case  the  supply  cable  must  be
positioned insuch a way that it can, at no
time, reach temperaures of more than 90°C.
After connection test the heating elements
by putting them into operation for abour 3
minutes.
The  manufacturers  decline  all
responsibility  for  damage  or
accidents in cases where  norms
have  not  been  observed  and
respected.
Electrical  connection
Only qualified personnel should install the appliance (place in cabinet and make
electrical  connection).  Every  operation  must  be  carried  out  with  appliance
disconnected from the electricity supply; when this is not possible the maximum
care is required when working on the appliance.