User Guide

13
For Ultimate Performance
2) Determine possible high-flow
situations that require a special
installation such as:
A. Water flow is higher than 80 gpm.
B. In-floor cleaner is included with pool.
C. Pool and spa combination with
common equipment.
NOTE: Over chlorination or damage to
the Cycler or other equipment could result
if these special installations are not used
in these situations.
B. With In-floor Cleaners
A. With High GPMS
Install T-fittings exactly as shown.
C. Pool and Spillover Spa Combination
TO POOL
TO SPA
3-WAY
CYCLER
CHECK VALVE
PUMP
TO POOL
CYCLER
➜➜
CYCLER
PUMP
3-WAY VALVE
®
1) Make sure back pressure Is between
3 and 8 psi
Higher back pressures result in over
chlorination. Lower back pressures result
in under chlorination. Adjust eye ball
fittings in the return jets to a larger size
to decrease back pressure or smaller
size to increase back pressure.
SUCTION
FROM
POOL/SPA
IN-FLOOR
VALVE
POOL WATER LEVEL
CHECK
VALVE
SUCTION
FROM
POOL/SPA