New Water Fresh and Clean ® Easy-Does-It Chlorine Pool-Care System The New Water Cycler and Replacement Cycler Pac ® Instruction Manual Customer Service 800-222-0169
TABLE OF CONTENTS Page No.
New Water ® Thank you for choosing New Water. This system will maintain a clean, clear swimming pool while you spend less time on maintenance and more time having fun! ® ® For In Ground Pools For Above Ground Pools ® New Water Cycler The New Water Cycler is on constant watch dispensing chlorine to control bacteria and provide a protective bank of sanitizer for your pool. Pool Balancing Water Balance Guidelines Free Chlorine: 1.0 - 3.0 ppm pH: 7.2 - 7.
New Water Cycler ® Installation The New Water Cycler comes in several different models. Please review this list, determine which model you have and follow the appropriate installation instructions for that model only. IN GROUND – Off-line ABOVE GROUND POOLS ® 15 1/4" Cycler Model # 430 Off-line for in ground pools ranging from 5,000 to 25,000 gallons. Uses a 7 lb. Cycler Pac. See Pages 9 and 10. Water ® 5 LBS. 1 1/2" i.d.
Parts List Model 400/430 In ground Model 100 Above ground 1 1 2 2 3 8 9 3 4 4 6 7 9 8&9 8 7 5 10 6 11 5 12 9 13 18 8 14 18 CYCLER DIAGRAM/PARTS LIST • Model 400 REF. # PART No. DESCRIPTION QTY. REQ.
TOOLS NEEDED Screwdriver Above Ground, Base Installation – Model 100 PUMP FILTER The Cycler should always be installed between the filter and pool (or between heater and pool if applicable). Wrench TO POOL MATERIALS NEEDED Teflon Tape Two Hose Adapters 1 1/2" X 1 1/2" X 1 1/4" Two Sections of of 1 1/2" Flex Hose (one provided with filter) teflon tape to the 2. 1. Apply threaded end of both hose adapters. Screw adapters into each end of Cycler. Tighten turning 1 to 2 revolutions with wrench.
TOOLS NEEDED Above Ground, Filter Installation - Model 100 Screwdriver Wrench 2. MATERIALS NEEDED Teflon Tape 1. Apply teflon tape to each Screw one end of nipple into the filter return. threaded end of nipple. Tighten turning 1 to 2 revolutions with wrench. DO NOT OVER TIGHTEN. either side of 3. Screw Cycler on to open nipple end until upright and secure. One 6" X 1 1/2" TBE PVC Nipple adapter into 5. Screw open end of Cycler. One Hose Adapter 1 1/2" X 1 1/2" X 1 1/4" teflon tape to 4.
In Ground, In-line Installation – Model 400 TOOLS NEEDED Wrench COPPER PIPE ® Hacksaw Install after all equipment and as far as possible from heater. Do NOT install in copper pipe as chemical corrosion occurs. 12" to 15" ® ® ® MATERIALS NEEDED ® Pipe Thread Sealant PVC Cement PIPE THRE AD SEAL ANT PVC CEMENT Do NOT install an in-line Cycler off-line as this Cycler is different than an off-line unit. 1. Two 2" Threaded X 2" or 1 1/2" Slip PVC Bushings (not included) 2.
TOOLS NEEDED In Ground, Off-line Installation – Model 430 Wrench Screwdriver ® Battery Operated Drill with 5/8" or 19/32" Bit. Install off-line when insufficient room for an inline application. Install as far from heater as possible. ® MATERIALS NEEDED Pipe Thread Sealant PVC Cement PIPE THRE AD SEAL ANT ® Do NOT install an off-line Cycler in-line as this Cycler is different than an in-line unit. Can be installed with the water flow in either direction due to its bi-flow control dial. 1. 2.
7. 8. 9. When pipe is totally dry, drill two 19/32" or 5/8" holes 12" apart on the return line. Be careful not to go through other side of pipe. Cut tubing to size for each Cycler connection and attach one to each elbow with clamps. Tighten clamps with a screwdriver. Screw elbow into reducer bushings on both sides. 11. Attach a gasket to each scoop. 10. 12. 13. Place scoops inside holes so the inlet scoop faces the water flow and the outlet scoop faces away from the water flow.
Replacing a Cycler Pac MIN. CAUTION Read Carefully – USE ONLY the factory recommended replacement Pac. (See label.) DO NOT USE any other Pac or bulk chemical tablets in the Cycler. Use of any other product could result in over chlorination, bleached liners, unsafe pool conditions, fire or explosion. Warranty will be void if the correct Pac is not used. MAX 1. Turn off pump. Turn dial to Minimum. This reduces the flow of water into the unit when the cap is open so isolation valves are unnecessary. 2.
Setting Control Dial 12 Hour Pump Run Time POOL SIZE Gallons Diameter PUMP SIZE 3/4 hp 1 hp 2 1 1/2 hp 2.5 24 Hour Pump Run Time 1 1/2 hp 1/2 hp 1.5 PUMP SIZE 3/4 hp 1 hp 1 1 1 1/2 hp 2 7,000 (18') 9,000 (21') 3 2.5 2 2 1.5 1 12,000 (24') 3.5 3 2.5 2 2.5 2 1.5 15,000 4 3.5 3 2.5 3 2.5 2 1.5 20,000 4.5 4 3.5 3 3.5 3 2.5 2 12 Hour Pump Run Time PUMP SIZE 1 hp 1 1/2 hp 3/4 hp 7,000 2.5 2 9,000 3 2.5 2 12,000 3.5 3 18,000 4.5 3.
For Ultimate Performance A. With High GPMS 1) Make sure back pressure Is between 3 and 8 psi Higher back pressures result in over chlorination. Lower back pressures result in under chlorination. Adjust eye ball fittings in the return jets to a larger size to decrease back pressure or smaller size to increase back pressure. Install T-fittings exactly as shown. CYCLER TO POOL CHECK VALVE SUCTION FROM POOL/SPA 2) Determine possible high-flow situations that require a special installation such as: A.
Cycler Maintenance Replacing the Control Dial O-Rings for Above Ground Cyclers Replacing the Control Dial O-Ring Kit for In Ground Cyclers 1. In the back of the Cycler depress tab at end of locking pin with a pen or screwdriver and pull pin out of dial. 1. Using a needle nose pliers, find the snap ring tail located at approximately the five o'clock position under the control dial. 2. Pull down and out of the groove. 2. Turn control dial back and forth as you pull it out of the housing. 3.
Replacing Cap O-rings Winterizing 1. Turn dial to minimum. Turn pump off . Unscrew side knob of Model 100 to relieve pressure. 1. Hold cap in front of you upside down with the o-ring groove facing up. Place one end of o-ring into cap groove at the point closest to you. Hold o-ring down with the thumb and forefinger of one hand. 2. Remove cap. 2. Take hold of the far end of the o-ring with the thumb and index finger of the other hand.
Limited One-Year Warranty King Technology, Inc. warrants to the original purchaser this unit will be free from any defects in workmanship and/or material, for a period of one (1) year from the date of original purchase. This warranty covers body, cap and control dial, but specifically excludes o-rings. King Technology at its option may replace any defective parts or the entire unit without charge after it is determined what is needed to correct any deficiency.