Product Manual A

12
CONNECTION INSTRUCTIONS
1. Check that your hose assembly valve is set to not allow gas flow. If you have an adjustable
regulator, turn the regulator control counterclockwise until it stops. This is the OFF position. If you
have a non-adjustable regulator with a manual valve(s), turn the manual valve(s) clockwise until
it stops. This is the OFF position.
2. Attach the regulator to the cylinder valve by turning the Type 1 fitting clockwise. Hand tighten with
the regulator positioned upright. Refer to the appropriate assembly diagram for the appliance,
page 10.
3. Perform the Leak Test:
4. Before lighting the cooker, check that the jet pipes, orifice
and venturi tube on cast burners are free from obstruction.
The orifice under the jet tube should be positioned pointing
up directly through the tube as per Figure 1. The orifice on
cast burners must be properly threaded into the venturi tube
as per instructions on page 10. Both situations must be
corrected if necessary before lighting to prevent flashback.
LP GAS CYLINDER INFORMATION
King Kooker
®
Outdoor Cookers are manufactured for use with 20lb. (9 kg) LP Gas Cylinders. Important
information to remember about LP Gas cylinders include:
1. Always read and follow the cylinder manufacturer’s instructions.
2. Make sure that the gas cylinder is not overfilled. The maximum weight of a properly filled 20 lb. (9 kg) LP
gas cylinder is approximately 38 lbs (17 kg). Never fill the cylinder beyond 80% full.
3. Make sure that the cylinder valve has the proper connection for a Type 1 appliance fitting.
4. Do not store a spare LP gas cylinder under or near this appliance.
5. Disconnect the cylinder from the cooker for storage.
6. Store the cylinder out of the reach of children.
7. Do not use or store the cylinder in a building, garage or enclosed area.
8. Always use a 20 lb. (9 kg) cylinder in the proper upright position for the proper vapor withdrawal. It should
also be stored and transported in the upright position.
9. The cylinder must have a protective collar to protect the cylinder valve.
10. Place dust cap on cylinder valve outlet whenever the cylinder is not in use. Only install the type of dust
cap on the cylinder valve outlet that is provided with the cylinder valve. Other types of caps or plugs may
result in leakage of propane.
11. Cylinder must be turned OFF while not in use.
ALWAYS READ AND FOLLOW THESE AND THE CYLINDER MANUFACTURER’S INSTRUCTIONS.
FAILURE
TO FOLLOW THESE INSTRUCTIONS AND WARNINGS COULD RESULT IN FIRE, EXPLOSION,
BURN HAZARD OR CARBON MONOXIDE POISONING WHICH COULD CAUSE PROPERTY
DAMAGE, PERSONAL INJURY OR DEATH.
LEAK TEST
Before lighting the appliance, a thorough leak test must be satisfactorily completed using
a non-ammonia soapy water solution (50% non-ammonia soap and 50% water). This is to be
applied with a small brush to all gas joints after the cylinder valve is opened (no more than
1/2 turn). If bubbles are seen, indicating a leak, turn off the cylinder and tighten the leaking
connection until a further leak test shows no leaks.
If tightening the connection does not stop the leak, call Metal Fusion, Inc. (800) 783-3885,
for assistance.
NEVER USE HOSE/REGULATOR ASSEMBLY IF LEAKING.
WARNING
CARBON MONOXIDE HAZARD
Burning charcoal inside can
kill you. It gives off carbon
monoxide, which has no odor.
NEVER burn charcoal inside
homes, vehicles or tents.
IMPORTANT: Read your cooker Instruction Manual before using�
this thermometer. The Red Zone is Danger. Never allow tem-�
perature of oil to exceed 350ûF. NEVER LEAVE COOKER
UNATTENDED. Failure to follow these instruc-�
tions could cause a grease fire / explosion result-
ing in personal injury, death, or property damage.
DEEP FRY THERMOMETER
WARNING
View from top of large jet pipe
FIGURE 1