User Manual

Note: Split bolt size not to exceed 1.0”
tall by 0.8” wide by 0.7” deep.
IMPORTANT: Turn off power before
installing or removing connector.
Product to be used in accordance with
local and national codes.
1. Assemble connection per split bolt
manufacturer instructions.
2. Lay conductor and connector into
housing per Figure 1.
3. Close lid of housing, aligning
conductors until housing lid is fully
latched.
4. Do not reuse.
Figure 1
Catalog # Selling Unit
69105 Bag of 10
Installation Instructions
www.kinginnovation.com
(P) 800.633.0232
(F) 636.519.5410
50100-82 REV A 02/13
For use with utility tracer lines
DryConn
®
Split Bolt Housing Aqua
U.S. Pat. 7,950,956 and additional Patents Pending apply.
All other trademarks, U.S. and Foreign Patents Pending apply.
All Rights Reserved.
MADE IN USA
PRODUCT SPECIFICATIONS
& MEASUREMENTS
Max. Voltage: 50V max.
Connector Size: 1.6” deep x 2.9” wide x 1” tall
Wire Range: #14-10 Solid Copper;
#14-10 Steel Core Tracer Wire
Sealant Temperature Rating: -50°C to 200°C
(-58°F to 392°F)
CONSTRUCTION
Housing: High impact polypropylene
Sealant: Dielectric silicone gel
MEASUREMENTS
A - 1.6” B - 2.9” C. 1”