ENGINEERING SPECIFICATIONS:
The original multi-watt steel fin
heater.ThisuniqueKingdesignallows
you to change the wattage of the
heaterbysimplydisconnectingacolor-
codedterminal.Butthebestfeature
ofthistrendsettingheaterishowquiet
it is. The high mass steel element
transfersheatquietlyandefciently.
This is our most popular heater for
asinglefamilyresidenceorupscale
condominium.Theelementhasave
yearwarrantyand20+yearhistoryof
reliability.
Thesleekappearancegivesthe
lookofaregistergrilleusedincentral
forcedairsystems.
Forthebestresultsusewithan
electroniclinevoltagewallthermostat.
PIC-A-WATT
®
/
THE ORIGINAL / FAN-FORCED
/
BEST
NOTE:Heaterscannotbeinstalled
vertically
SLP
SMART
LIMIT
PROTECTION
®
U.S. PATENT #6,748,163 B2 • CIPO PATENT #2,393,882
SLP
SMART
LIMIT
PROTECTION
®
U.S. PATENT #6,748,163 B2
CIPO PATENT #2,393,882
ContractorshallsupplyandinstallPAWSerieswall-mountedforced-air
electricheatersmanufacturedbyKingElectricalMfg.Company,ofthe
wattageandvoltageasindicatedontheplans.
Ratings:Heatersshallbeavailableinwattagesof250to2,250at120,
208,240,or277Volts.
Blower and Motor:Atangentialcylindricalblower,delivering65CFM,
shallbedrivenbyashadedpole,permanentlylubricated,C-frametype
motorwithimpedanceprotectionandsealedbearings.Motorsshallbe
thesamevoltageastheheater.
Elements:Elementassembliesshallbeanon-glowingdesign.Element
assemblies shall consist of three steel sheathed heating tubes in a
furnace-brazed,plate-nned,blockdesign.Eachsheathedtubeshall
containcoiledNi-ChromewireembeddedinaninsulatorofMagnesium
Oxide.The element assembly shallprovide a minimum of seven (7)
possible wattage congurations availablefor selection during eld
installation.Theuseofexternalresistors,diodes,orotherweaklinksto
obtainmultiplewattageswillnotbeacceptable.
Thermal Overload:Heatersshallbeequippedwiththermaloverload
Smart Limit Protection®,whichdisconnectselementsandmotor
intheeventnormaloperatingtemperaturesareexceeded.Ifthermal
overload trips due to abnormal operating temperatures, thermal
overloadshallremainopenuntilmanuallyresetbyturningtheheater
offforfteenminutes.Automaticresetofthermaloverloads,which
allowtheelementtocontinuetocycleunderabnormalconditions,
willnotbeaccepted.
Wall Can:Thewallcanshallbe20gaugeelectrogalvanizedsteeland
shallcontainaminimumofthree(3)knockoutsthroughwhichpower
leadsarebrought.Thewallcanshallhaveadepthgaugeindicator,
andafactoryinstalled,insulatedandstrandedcoppergroundwire.
Minimum4”clearancetooorsand6”sidewalls.Zeroclearanceto
combustiblesinthewall.
Grille:Thegrilleshallbealouvered,one-piecedesignwithrounded
edgesonallfoursides,withroundedcornerstopreventsnagsfrom
contactwithothermaterials.Thegrilleshallbeepoxypowder-coated
inwhiteoralmond.
Approvals: cULus(E41422)
•1-Poleor2-Poleunit-mount
thermostat45°-80°F
•Surfacewallbox
•Color:almond(-A)
•ULTRAcustombargrille
•Stainlesssteel(refertoindex)
OPTIONS
E41422