Cut Sheet

Cove HeaterKCV Series
Dimensional Data
Engineering Specifications
Construction:
Constructed of extruded aluminum with a maximum cross section
thickness of .962”.
With sawtooth profile to increase radiating surface area.
Open on top and bottom for maximum convection heating room air.
With 32 cubic inch junction box at both ends, furnished with 1/2”
knockouts on back and top.
Ni-Chrome wire embedded in Magnesium Oxide powder enclosed
and sealed in aluminum sheath.
Element wattage density of approximately 150 watts per linear foot.
With full length back case constructed of 22 gauge electrogalvanized
steel with baked enamel finish.
Two year limited warranty.
Ratings and Approvals:
The heaters shall be available in ratings from 250 - 1800 watts
at 120 and 208/240 Volts.
cULus
MODEL SHIP WEIGHT lbsDESCRIPTION
KCVT-1R
KCVT-1L
KCVT-2R
KCVT-2L
Single Pole Right side wiring thermostat
Single Pole left side wiring thermostat
Double Pole Right side wiring thermostat
Double Pole Left side wiring thermostat
.25
.25
.25
.25
-W
White
Accessories/Options
-04-09
Joint Cover (To Combine 2 KCVs) Almond
.09
-04-09-W
Joint Cover (To Combine 2 KCVs) White
.09
-A
Almond
24" to 118"
4
3 3/8
3 3/16
3 7/8
DETAIL A
SCALE 1 : 2
MOUNTING HOLES
8" ON CENTER
1 9/16"
1 11/16"
DETAIL C
SCALE 1 : 2
BACK VIEW
1"
1 11/16"
DETAIL B
SCALE 1 : 2
TOP VIEW
Heaters are not to be mounted closer than 2½” from drywall ceiling or 6” from vinyl or drop ceiling.
Heaters to be mounted at least 6 feet from floor.
MINIMUM CLEARANCE
Radiant:
Heat produced is emitted as
radiant infrared invisible rays
Convection:
Heat produced is also transmitted by natural
convection from the top of the heater
Cold Air
Warm Air