Instructions / Assembly

4
Rev 4.14.22
Series
Heater
Waage
Lamp
Quanty
Minimum
Mounng Height
(Ft)
Recommended
Mounng Height
[Dim. A]
Recommended
Distance Between
Heaters (Ft)*
[Dim. B]
RK 1500W 1 7'9"' 8' to 9' 5' to 10'
NOTE: Minimum Clearances to combusbles published in this manual and on safety labels must
be maintained at all mes. Factory recommended mounng heights are listed as a guideline.
If infrared heaters are mounted too low or too high, they may result in discomfort or lack of
heat. Test surrounding materials to verify that nothing is geng hoer than expected.
Heang Applicaon Chart
Heang Applicaon Diagram
Series
Heater
Waage
Lamp
Quanty
AVERAGE Cov-
erage Of Heater
Length X Width (Ft.)
*COLD/WINDY
Coverage Of Heater
Length X Width (Ft.)
**PROTECTED
Coverage Of Heater
Length X Width (Ft.)
RK 1500W 1 5’ x 5’ 3’ x 3’ 7’ x 7’
NOTES: *Heaters can provide less than average coverage in extremely cold/windy condions.
**Indoor or well-protected environments will generally exceed average coverage areas.
Coverage Area Chart