KFS Series Installation Manual

72
KFS Furnace Airflow Delivery Chart
Case Size HP Speed
CFM (Static)
(0.1) (0.2) (0.3) (0.4) (0.5) (0.6) (0.7) (0.8)
Small Case
30.5” tall
1/5
Low 1090 980 940 890 840
820 800 760
Med 1260 1090 1040 980 930
890 810 780
High 1370 1260 1220 1170 1120
1090 1080 990
1/3
Low 1700 1680 1670 1660 1650
1640 1630 1620
Med 1810 1800 1790 1750 1740
1730 1720 1710
High 1960 1940 1930 1910 1870
1860 1850 1830
Large Case
30.5” tall
1/5
Low 1160 1120 1090 1050 1020
990 960 850
Med 1310 1230 1200 1150 1120
1050 990 910
High 1480 1410 1390 1270 1240
1180 1120 1040
1/3
Low 1860 1850 1840 1830 1820
1810 1790 1740
Med 2000 1980 1960 1940 1930
1920 1910 1900
High 2120 2100 2070 2050 2030
2020 2010 2000
Airflow delivery chart notes:
1. CFM = cubic feet per minute.
2. Static = water column inches.
3. Performance based on air properties at sea level.
4. Includes factory provided air filter installed.
5. Includes electric heating coils installed, no power applied, no heat resistance.
6. Based on 230V, 3 speed motor.
7. 480V motors are single speed only, use high speed for airflow delivery.
Rev 10.15.12