By Paul Aylett at 5:05 pm, Aug 21, 2012 TENS Period Pain Reliever User Manual PPT 1 Series
Content Introduction 2 Parts 3-4 General Warnings and Safety 5-7 Instructions for use 8 - 13 Programme Selection 14 Gel Pad Positioning 15 Battery Information 16 Specification 17 Troubleshooting 18 Maintenance and Cautions 19 Storage 20 Disposal 21 Warranty 22 Explanation of Symbols on Unit 23
Introduction Thank you for purchasing the Kinetik TENS Period Pain Reliever (Model PPT1). The TENS Period Pain Reliever is a TENS machine and highly effective in relieving period pain and menstrual cramps. TENS stands for Transcutaneous Electrical Nerve Stimulation and is recognised as a safe and highly effective method of relieving pain. TENS is now regularly recommended by doctors, physiotherapists and pharmacists throughout the UK.
Parts About TENS Period Pain Reliever Your TENS Period Pain Reliever is supplied with a storage bag containing: A. TENS UNIT B. 1 GEL PAD C. USER MANUAL D.
Parts Intensity lock indicator Low battery indicator Program indication Treatment time unit indicator Treatment time indicator Intensity indication Program or intensity number indication 4
General Warnings and Safety Before you start: Please carefully read and understand the following warnings and cautions to ensure the safe and correct use of this device and to prevent injury. • Make sure the batteries are installed correctly. • Connect the cables to the gel pad and then connect to the unit (see page 8 for more details). • Attach the gel pad to the area of pain. Please see section ‘Gel Pad Positioning' for details of where to place the pad (page 15).
General Warnings and Safety • Patients must consult their doctor before using this device if receiving any physical therapy or suffering from any of the following: Acute diseases º Heart diseases or heart rhythm problems º A fever º Abnormal blood pressure º Skin conditions including broken or damaged skin and people with loss of feeling in areas º of the body • Do not use the device with an electrocardiograph meter (ECG) or any other medical equipment.
General Warnings and Safety Please stop using the TENS Period Pain Reliever immediately if you notice any reddening of your skin, if you feel any discomfort or feel unwell seek medical advice. Improper use of the Period Pain Reliever can lead to harm and damage. For safe use of the product, please note the following safety instructions: • The unit must be turned off before moving the gel pad to different parts of the body. • Keep the unit out of the reach of children.
Instructions for Use How to connect the gel pad to the cables: Adhesive Gel Pad Connection Cables Transparent Film III I IV II Caution: Always use the correct Kinetik TENS Period Pain Reliever Replacement Pads (PPT 1) with this device. Replacement gel pads are available from your local pharmacist. Ensure the device is completely switched off. Attach the gel pad to the cables as shown (see pictures I and II) above. Ensure the gel pad connections are connected to the cables (see picture III).
Instructions for Use Caution: Before applying the self-adhesive gel pad, it is recommended that you wash your skin, to remove any lotions or moisturisers, then dry thoroughly. Do not switch the device on when the self-adhesive gel pad is not positioned on the body. Never remove the self-adhesive gel pad from the skin whilst the device is still switched on. For hygiene reasons we recommend that the gel pad is replaced every 30 days. The Period Pain Reliever can be used twice a day for 20 minutes at a time.
Instructions for Use The Kinetik TENS Period Pain Reliever comes with 8 programs for you to select from. We recommend that you try each program to select the one that provides you with the most relief. (see page 14 for a list of programs) Select the program: Press [ off/ p/▼] button to select the treatment program. Starting the treatment: Press [ on/▲ ] button to adjust the output intensity and the device will start to work.
Instructions for Use Adjust the intensity: Pressing [ on/▲ ] to increase the intensity. Pressing [ off/ p/▼ ] to decrease the intensity. The device will return to standby mode when the intensity is set to zero.
Instructions for Use Lock function: When the reliever is in use, for safety the [ on/▲ ] and [ off/ p/▼ ] buttons will be locked automatically when no buttons are pressed for 5 seconds. Press the [ off/ p/▼ ] button to unlock. Low battery indicator: When the low power indicator flashes, the batteries should be replaced with new ones as soon as possible. However, the TENS Period Pain Reliever will continue to operate for several more hours.
Instructions for Use Turn the device off: Press and hold the [ off/ p/▼ ] button for 3 seconds to turn off the device. To replace the batteries, open the lid cover and remove the batteries. Replace with new batteries (2 x AAA), observing the correct polarity.
Programme Selection The Kinetik TENS Period Pain Reliever comes with 8 programs for you to select from. We recommend that you try each program to select the one that provides you with the most relief.
Gel Pad Positioning Attach the gel pad firmly to the area of pain Do not position the gel pad directly over the spine. If you find the gel pad becomes less sticky after use, disconnect it from the Period Pain Reliever and gently moisten the gel with clean, cold water using your finger. For Hygiene reasons, it is recommended that you replace the gel pad every 30 days.
Battery Information Insert 2 batteries (type AAA) into the battery compartment. Make sure you are installing the batteries correctly. Be sure to match the positive and negative ends of the batteries to the markings in the battery compartment of the device. Check batteries 1. Please use 2 x AAA batteries in the unit. 2. Remove the batteries if the product is not in use for long periods of time. 3. Do not mix old and new batteries or different types of batteries. 4.
Specification • • • • • • • • • • • Power Sources: 2 x AAA batteries Frequency: 2 - 120 Hz Pulse Duration: 50-250µs Output Voltage: 60V (P-P) ±20% by 500 Ω load Size 57mm x 55mm x 14.5mm (approx.
Troubleshooting Problem Check points Possible solution The unit does not switch on Are the batteries exhausted? Are the batteries installed correctly? Replace the batteries. Insert the batteries observing correct polarity. No output stimulus/sensation Is the cable properly connected? Firmly connect the cable. Have you removed the transparent protective film from the gel pad? Remove the protective film.
Maintenance and Cautions SAFETY CAUTIONS • Do not immerse device in water or any liquid. Do not drop the device or throw it from a height. • After using the device, please remove the output plug from the output socket and re-attach the pad to the protective transparent film. • Always use the protective film when the pad is not in use. • Do not twist or pull the output cable. • Do not use any chemical to clean the main unit or the gel pad. If you need to clean them, please wipe with a damp, lint free cloth.
Storage Remove the batteries from the unit if you are not going to use it for a long period of time. Leaking batteries can damage the unit. Do not make any sharp kinks in the connecting leads or electrodes. After use, stick the gel pad onto the protective plastic film. Do not expose the device to direct sunlight and protect it against dirt and moisture. Store the device in a cool, well-ventilated place. Never place any heavy objects on the device.
Disposal Used, fully discharged batteries must be disposed of in a specially labeled collection container, at toxic waste collection points or through an electrical retailer. You are under legal obligation to dispose of batteries correctly. NOTE: You will find these markings on batteries containing harmful substances : Pb = battery containing lead, Cd = battery containing cadmium, Hg = battery containing mercury.
Warranty This product is guaranteed for a period of one year from the date of purchase against mechanical and electrical manufacturing defects. There are no user serviceable parts inside the instrument. Any attempted repair by unauthorised persons invalidates the warranty. This does not affect your statutory rights.
Explanation of Symbols on Unit Read the Instructions. This symbol indicates that this product is a Type BF device. Symbol for "Environment Protection" – Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local Authority or retailer for recycling advice. Symbol for “Manufacturer”. 0197 This product complies with MDD93/42/EEC requirements. Symbol for “European Representative”. Harvard Medical Devices Ltd.