SDS
_____________________________________________________________________________________________
1422845 - Lead Acid (Non-Spillable) Battery Revision Date 26-Oct-2017
7. HANDLING AND STORAGE
Precautions for safe handling
Advice on safe handling
Handle in accordance with good industrial hygiene and safety practice. Avoid contact with
skin, eyes or clothing. In case of insufficient ventilation, wear suitable respiratory
equipment. Handle product only in closed system or provide appropriate exhaust
ventilation. Do not eat, drink or smoke when using this product. Take off contaminated
clothing and wash before reuse. Remove contaminated clothing and shoes. Do not breathe
dust. Avoid generation of dust.
Conditions for safe storage, including any incompatibilities
Storage Conditions
Keep containers tightly closed in a dry, cool and well-ventilated place. Keep out of the reach
of children. Protect from moisture. Store away from other materials. Store locked up.
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Control parameters
Exposure Limits
.
Chemical name ACGIH TLV OSHA PEL NIOSH IDLH
Lead
7439-92-1
TWA: 0.05 mg/m
3
TWA: 50 µg/m
3
TWA: 50 µg/m
3
Pb
Action Level: 30 µg/m
3
Poison;See 29 CFR 1910.1025
Action Level: 30 µg/m
3
Pb
Poison;See 29 CFR 1910.1025
IDLH: 100 mg/m
3
IDLH: 100
mg/m
3
Pb
TWA: 0.050 mg/m
3
TWA: 0.050
mg/m
3
Pb
Sulfuric acid
7664-93-9
TWA: 0.2 mg/m
3
thoracic
particulate matter
TWA: 1 mg/m
3
(vacated) TWA: 1 mg/m
3
IDLH: 15 mg/m
3
TWA: 1 mg/m
3
Copper
7440-50-8
TWA: 0.2 mg/m
3
fume TWA: 1
mg/m
3
Cu dust and mist
TWA: 0.1 mg/m
3
fume
TWA: 1 mg/m
3
dust and mist
(vacated) TWA: 0.1 mg/m
3
Cu
dust, fume, mist
IDLH: 100 mg/m
3
dust, fume
and mist IDLH: 100 mg/m
3
Cu
dust and mist
TWA: 1 mg/m
3
dust and mist
TWA: 0.1 mg/m
3
fume TWA: 1
mg/m
3
Cu dust and mist
Chemical name Alberta British Columbia Ontario TWAEV Quebec
Lead
7439-92-1
TWA: 0.05 mg/m
3
TWA: 0.05 mg/m
3
TWA: 0.05 mg/m
3
TWA: 0.05 mg/m
3
Sulfuric acid
7664-93-9
TWA: 1 mg/m
3
STEL: 3 mg/m
3
TWA: 0.2 mg/m
3
TWA: 0.2 mg/m
3
TWA: 1 mg/m
3
STEL: 3 mg/m
3
Copper
7440-50-8
TWA: 0.2 mg/m
3
TWA: 1 mg/m
3
TWA: 1 mg/m
3
TWA: 0.2 mg/m
3
TWA: 0.2 mg/m
3
TWA: 1 mg/m
3
TWA: 0.2 mg/m
3
TWA: 1 mg/m
3
Other Exposure Guidelines
Vacated limits revoked by the Court of Appeals decision in AFL-CIO v. OSHA, 965 F.2d 962
(11th Cir., 1992). See section 15 for national exposure control parameters.
Appropriate engineering controls
Engineering controls
Showers
Eyewash stations
Ventilation systems.
Individual protection measures, such as personal protective equipment
Eye/face protection
Face protection shield.
_____________________________________________________________________________________________
Page 5 / 13