User's Manual
Whenever the alarm is operating, the green Power LED flashes every 30 
seconds to indicate the unit is monitoring for CO. If the alarm senses 
dangerous levels of CO, the red Alarm LED will flash and the alarm will 
emit an audible alarm pattern. 
5. Model KN-COB-B-LPM Operating Characteristics
Operating and Alarm Characteristics
Function  LED Display  Alarm Sound  Unit Status  Recommendation
Normal
Operation
Green LED 
flashes every 30 
seconds
None Normal DC 
operation (sensing 
no CO) and with 
good batteries
None
Carbon 
monoxide 
alarm
Red LED flashes 
with beeps. 
4 quick beeps, 
5 seconds 
silence, 
repeating
Alarm condition.
Dangerous con-
centrations of CO 
detected
Refer to “What to 
do When the Alarm 
Sounds” (inside front 
cover)
Low 
battery
Red LED flashes 
every 60 seconds
One quick 
beep every 
60 seconds
Batteries need to be 
replaced
Replace all three AA 
batteries 
Error / 
service 
alarm
Red LED flashes 
every 30 seconds
One quick 
beep every 
30 seconds
Unit is in error 
condition
Error Red LED 
constantly on
Constant 
alarm
Very low battery or 
unit malfunction
Replace battery. 
If condition continues, 
unit has malfunc-
tioned. Replace 
immediately. Unit will 
not respond to CO
Normal 
Test/Reset 
function
Red LED flashes 
with beeps.
4 quick beeps, 
5 seconds 
silence, 
repeated once
Normal operation 
when Test/Reset 
button is pressed
CO not detected. 
Alarm for test pur-
poses only
End of 
unit life 
indicator
Red LED flashes 
two times
every 30 seconds
Two quick 
beeps every 
30 seconds
End of unit life Replace unit imme-
diately. Unit will not 
respond to to CO
6. Model KN-COPP-B-LPM (with digital display) 
 Operating Characteristics
When the unit is first powered up, the green Operate LED flashes 
once every 30 seconds and the digital display will show three “eights” 
– indicating the alarm is in the start-up mode. The three “eights” will 
remain for approximately 30 seconds. Then, the alarm will display “0” 
and begin monitoring the air for CO and will continue to do so as long 
as it receives power.
This alarm will display a “0” if CO concentrations between 0 and 30 
PPM have been detected within the last 15 seconds.
2529-7209-01(21008094C).indd 142529-7209-01(21008094C).indd 14 13-3-12 上午11:5613-3-12 上午11:56