LED Display Shows Alarm Sound Unit Status Recommendation
Steady “Err”
Red LED flashes every
30 seconds
One quick
beep every
30 seconds
Unit malfunction Press the Test/Reset
button. If “Err” con-
tinues, unit has mal-
functioned. Replace
immediately. Unit will
not respond to CO
6. Model KN-COPF-i Operating Characteristics
No display alternating
with display of CO
concentration every 60
seconds. Red LED
flashes with beeps
4 quick beeps,
5 seconds
silence,
repeating
every 60 secs
Alarm condition
powered on battery
backup. Dangerous
concentrations of
CO detected
Refer to “What to do
When the Alarm
Sounds” (inside front
cover).
Replace battery
No display alternating
with “0” every 60
seconds.
Green LED flashes
every 30 seconds
None Normal operation
after first 4 minutes
of battery backup
operation. Unit
monitoring for CO
Verify AC power is
restored as soon as
possible to maintain
battery.
Peak Level Memory
When the Peak Level button is pressed and held, the display shows the
highest CO reading taken by the CO alarm since its last reset or power
up. The Peak Level display feature will display levels between 11-999
PPM. Although the Peak Level feature will display levels below 30 PPM,
these levels will not result in an alarm no matter how long the device is
exposed to these levels. The Peak Level feature is helpful in identifying if
you have had a CO reading since resetting the alarm.
Concentrations of CO between 1 and 30 PPM can often occur in nor-
mal, everyday conditions. Concentrations of CO below 30 PPM may be
an indication of a transient condition that may appear today and never
reappear. Some CO conditions may start out as low level leaks but could
develop into CO concentrations that may become harmful.
Peak Level Memory Reset
Press the Peak Level button; with the button still pressed, press the
Test/Reset button for two seconds and release. The number on the dis-
play will turn to “0”, the memory will be cleared and the alarm will
begin monitoring for CO. The Peak Level memory is also reset when the
unit loses power.
“End” displayed.
Red LED flashes
every 30 seconds
One quick beep
every 30 seconds
End of unit life Replace unit immedi-
ately. Unit will not
respond to CO.
2527-7201-00(820-1387A):_ 2008.5.12 9:35 AM Page 17