Owner's Manual

WIRING ADAPTER FOR
USE WITH FIREX
®
WIRING HARNESS
User’s Guide
The Kidde and Firex alarm models listed in this user guide
have been tested to be interconnect compatible. That
compatibility exists with or without the use of the wiring
harness adapters.
Model KA-F wiring adapter, for use with Firex
®
wired -in smoke alarm
power harnesses.
WARNING! IF THE SMOKE ALARM BEING REPLACED IS INSTALLED IN A
LOCATION REQUIRED BY THE BUILDING CODE, AN ALARM WITH SMOKE
SENSING CAPABILITIES MUST BE REINSTALLED AT THAT LOCATION.
IMPORTANT! READ ALL INSTRUCTIONS BEFORE INSTALLATION AND
KEEP THIS GUIDE FOR FUTURE REFERENCE.
Read and become familiar with the operating manual and all other
literature supplied with each alarm in your home.
Warning! If the power harness currently wired into the structure does
not match the photo in figure 1, this is not the correct wiring adapter
for your application.
THIS ADAPTER CAN ONLY BE USED WHEN REPLACING FIREX
®
MODELS;
FADC, ADC, AND AD. THESE MODELS HAVE BEEN TESTED FOR
INTERCONNECT COMPATIBILITY WITH THE KIDDE ALA
RM MODELS; 1235,
1275, 1276, 1285, i12020, i12040, i12060, i12080, i4618, PE120, PI2000,
KN-COSM-IB, KN-COB-IC, KN-COP-IC, AND RF-SM-ACDC.
Q U ES T IO N S OR F O R M O R E I NF OR MA T IO N
Ca ll our C on su mer Ho tl i ne a t
1 - 80 0 -8 8 0- 6 788
Or co nt a c t u s at our we b s i te ww w. kid d eU S .co m
F I R E X
®
i s a re g i stered tr a d ema rk o f Ma ple C ha s e Com pa n y
U.S. Patent No. 6,976,883
C ustom assemble d in C h i n a with u . s . an d f oreig n compon e n t s
P/ N 8 20- 1 42 7 Re v E
FIVE YEAR LIMITED WARRANTY
KIDDE Safety warrants the original purchaser that the enclosed smoke
alarm adapter will be free of defects in material and workmanship or
design under normal use and service for a period of five years from the
date of purchase. The obligation of KIDDE Safety under this warranty is
limited to repairing or replacing the smoke alarm adapter which we find
to be defective in material, workmanship or design, fre
e of charge to the
customer, upon sending the smoke alarm adapter with proof of date of
purchase, postage and return postage prepaid to: Warranty Service
Department, Kidde Safety, 1394 South Third St, Mebane, NC 27302.
THE LIABILITY OF KIDDE SAFETY OR ANY OF ITS PARENT OR
SUBSIDIARY CORPORATIONS ARISING FROM THE SALE OF THIS
SMOKE ALARM ADAPTER OR UNDER THE TERMS OF THIS LIMITED
WARRANTY SHALL NOT IN ANY CASE EXCEED THE COST OF
REPLAC
EMENT OF THE SMOKE ALARM ADAPTER AND IN NO CASE
SHALL KIDDE SAFETY OR ANY OF ITS PARENT OR SUBSIDIARY
CORPORATIONS BE LIABLE FOR CONSENSEQUENTIAL LOSS OR
DAMAGE RESULTING FROM THE FAILURE OF THE SMOKE ALARM
ADAPTER OR THE BREACH OR THIS OR ANY OTHER WARRANTY,
EXPRESSED OR IMPLIED, EVEN IF THE LOSS IS CAUSED BY THE
COMPANIES NEGLIGENCE OR FAULT.
Since some states do now allow limitations on the duration of an implied
warranty or do not allow
the exclusion of limitations or incidental or
consequential damages, the above limitation or exclusions may not apply
to you. While this warranty gives you specific legal rights, you may also
have other rights, which vary, from state to state.
The above warranty may not be altered except in writing signed by both
parties hereto.
This smoke alarm adapter allows the installation of new Kidde alarm to existing
Firex
®
wiring harnesses. When using this adapter, the power harness supplied
with your new Kidde alarm is not used. You will need to remove the existing
Firex
®
mounting plate and install the mounting plate supplied with your new
Kidde alarm. Connect
the KA-F adapter to the Firex
®
wiring harness then attach
your Kidde alarm to the adapter (figure 2). Secure the Kidde alarm to the mounting
plate.
After installation, be sure that the AC power indicator is operating and test
all your alarms following the instructions supplied by the alarm manufacturer
for your specific alarm model. If the alarms are interconnected push the
test button on each alarm and verify that all the interconnected alarms
sound when any alarm is activated. The interconnect system should not
exceed the NFPA interconnect limit of 12 s
moke alarms.
In addition to the alarms that are compatible with the use of the adapter
Firex® smoke alarm models PAD (4480), and FADCP can be interconnected
with the Kidde® smoke alarm models listed in the adapter section plus the
following models of alarm products: Silhouette smoke alarm model KN-
SMFM-I, heat alarm HD135F, Strobe light SL177I, Power supply relay
module SM120X
Each alarm shall be installed and tested in accordance with its instruction
manual.
F I G U R E 1
F I G U R E 2

Summary of content (1 pages)